Skip Navigation



The European Journal of Orthodontics Advance Access published online on February 2, 2009

The European Journal of Orthodontics, doi:10.1093/ejo/cjn104
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
31/3/260    most recent
cjn104v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Daems, J.
Right arrow Articles by Willems, G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Daems, J.
Right arrow Articles by Willems, G.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author 2009. Published by Oxford University Press on behalf of the European Orthodontic Society. All rights reserved. For permissions, please email: journals.permissions@oxfordjournals.org.

Morphological characterization of as-received and in vivo orthodontic stainless steel archwires

Julie Daems*, Jean-Pierre Celis** and Guy Willems*

* Department of Orthodontics, Katholieke Universiteit Leuven, Belgium
** Department of Metallurgy and Materials Engineering, Katholieke Universiteit Leuven, Belgium

Address for correspondence Dr Guy Willems, Department of Orthodontics, Faculty of Medicine, School of Dentistry, Oral Pathology and Maxillofacial Surgery, Katholieke Universiteit Leuven, Kapucijnenvoer 7, B-3000 Leuven, Belgium E-mail:guy.willems{at}med.kuleuven.be


   Abstract

This study was undertaken to evaluate the material degradation of clinical bracket-archwire-contacting surfaces after in vivo orthodontic use. Twenty-four stainless steel multiloop edgewise archwires with two different cross sections (0.016 x 0.016 and 0.016 x 0.022 inches) were used for at least 6 months in the mouths of 14 patients. The surfaces of both as-received (cross-section of 0.016 x 0.016, 0.016 x 0.022, and 0.017 x 0.025 inches) and the in vivo wires were examined using scanning electron microscopy.

The as-received wires exhibited an inhomogeneous surface with different surface irregularities resulting from the manufacturing process. For the in vivo archwires, an increase in the variety, type, and number of surface irregularities were observed. Crevice corrosion occurred not only at surface irregularities formed during manufacturing and orthodontic handling but also at the bracket-archwire-contacting surfaces and at the archwire surfaces coated with plaque and food remnants. This corrosion may be linked to the formation of a micro-environment at these locations. In addition, a limited number of signs of degradation induced during in vivo testing due to wear and friction were observed.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.