Skip Navigation



The European Journal of Orthodontics Advance Access published online on February 8, 2008

The European Journal of Orthodontics, doi:10.1093/ejo/cjm112
This Article
Right arrow Full Text Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow All Versions of this Article:
30/2/190    most recent
cjm112v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by De Santis, R.
Right arrow Articles by Nicolais, L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by De Santis, R.
Right arrow Articles by Nicolais, L.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author 2008. Published by Oxford University Press on behalf of the European Orthodontic Society. All rights reserved. For permissions, please email: journals.permissions@oxfordjournals.org.

The Eulerian buckling test for orthodontic wires

R. De Santis*, F. Dolci**, A. Laino***, R. Martina***, L. Ambrosio* and L. Nicolais*

* IMCB-CNR Institute of Composite and Biomedical Materials, National Research Council, Naples
** Unità Operativa di Ortognatodonzia, PTV Azienda Ospedaliera Universitaria, Policlinico Torvergata, Rome
*** Department of Odontostomatological and Maxillo-Facial Science, University of Naples "Federico II", Italy

Address for correspondence Roberto De Santis, IMCB-CNR, Institute for Composite and Biomedical Materials, National Research Council, Piazzale Tecchio 80, Naples 80125, Italy, E-mail: rosantis{at}unina.it


   Abstract

Orthodontic treatment is mainly dependent on the loads developed by metal wires. The load developed by a buckled orthodontic wire is of great concern for molar distalization and cannot be simply derived from mechanical properties measured through classical tests (i.e. tensile, torsion, and bending). A novel testing method, based on the Eulerian approach of a simple supported beam, has been developed in order to measure the load due to buckling of orthodontic wires. Elastic titanium molybdenum alloy (TMA; SDS Ormco) and superelastic Nitinol (3M Unitek) and copper nickel–titanium (NiTi; SDS Ormco) wires, each having a rectangular cross section of 0.016 x 0.022 square inches (0.41 x 0.56 mm2), were used. The wires were activated and deactivated by loading and unloading. In order to analyse thermo-mechanical properties in buckling, mechanical tests were assisted by calorimetric measurements through differential scanning calorimetry (DSC). Statistical analysis to determine differences between the samples was undertaken using two-way analysis of variance (ANOVA) and Tukey's post hoc test, and one-way ANOVA to assess differences between the tested wires under similar conditions and different materials.

The results suggest that the load due to buckling depends on material composition, wire length, the amount of activation, temperature, and deformation rate. The results can be considered as the lower bound for the loads experienced by teeth as far as a buckled wire is concerned. At a temperature higher than the austenite finish transition temperature, superelastic wires were strongly dependent on temperature and deformation rate. The effect due to an increase of deformation rate was similar to that of a decrease of temperature. Load variations due to temperature of a superelastic wire with a length of 20 mm were estimated to be approximately 4 g/°C. The high performance of an applied superelastic wire may be related to the high dynamics of the load in relation to temperature.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.