The European Journal of Orthodontics Advance Access published online on February 22, 2007
The European Journal of Orthodontics, doi:10.1093/ejo/cjl086
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Biomechanical finite-element investigation of the position of the centre of resistance of the upper incisors
Department of Orthodontics, University of Bonn, Germany
Address for correspondence Christoph Bourauel, Department of Orthodontics, University of Bonn, Welschnonnenstrasse 17, 53111 Bonn, Germany, E-mail: bourauel{at}uni-bonn.de
| Abstract |
|---|
The position of the centre of resistance (CR) is an essential parameter regarding the planning of orthodontic tooth movements. In the present investigation, the combined CR of the upper four incisors was determined numerically using the finite-element (FE) method.
Based on a commercially available three-dimensional data set of a maxilla, including all 16 teeth, as well as known and earlier determined material parameters, FE models of the upper incisors and their surrounding tooth-supporting structures were generated. In the FE system, the model of the anterior segment was loaded with torques of 10 Nmm each at the lateral incisors.
The FE model indicated that the individual incisors moved independently, although they were blocked with a steel wire of dimension 0.46 x 0.65 mm2. The individual CRs were located at 5 mm distal and 9 and 12 mm apical to the centre of the lateral brackets. Thus, the classical view of a combined CR for the anterior segment was disproved and the planning of orthodontic tooth movements of the upper incisors should no longer be based on that concept.
![]()
CiteULike
Connotea
Del.icio.us What's this?
This article has been cited by other articles:
![]() |
O. Polat-Ozsoy, A. Arman-Ozcirpici, and F. Veziroglu Miniscrews for upper incisor intrusion Eur J Orthod, August 1, 2009; 31(4): 412 - 416. [Abstract] [Full Text] [PDF] |
||||