Skip Navigation

The European Journal of Orthodontics 2008 30(3):233-238; doi:10.1093/ejo/cjn005
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Morina, E.
Right arrow Articles by Bourauel, C.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Morina, E.
Right arrow Articles by Bourauel, C.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author 2008. Published by Oxford University Press on behalf of the European Orthodontic Society. All rights reserved. For permissions, please email: journals.permissions@oxfordjournals.org.

Torque expression of self-ligating brackets compared with conventional metallic, ceramic, and plastic brackets

Enver Morina*,**, Theodore Eliades***, Nikolaos Pandis****, Andreas Jäger** and Christoph Bourauel*

* Department of Oral Technology
** Department of Orthodontics, School of Dentistry, University of Bonn, Germany
*** Department of Orthodontics, School of Dentistry, Aristotle University of Thessaloniki, Greece
**** Private Orthodontic Practice, Corfu, Greece

Address for Correspondence Professor Christoph Bourauel, School of Dentistry, University of Bonn, Welschnonnenstr. 17, 53111 Bonn, Germany, E-mail: bourauel{at}uni-bonn.de


   Abstract

The purpose of this research was to investigate the torque capacity of active and passive self-ligating brackets compared with metallic, ceramic, and polycarbonate edgewise brackets. Six types of orthodontic brackets were included in the study: the self-ligating Speed and Damon2, the stainless steel (SS), Ultratrimm and Discovery, the ceramic bracket, Fascination 2, and the polycarbonate bracket, Brillant. All brackets had a 0.022-inch slot size and were torqued with 0.019 x 0.025-inch SS archwires. For this purpose, the labial crown torque of an upper central incisor was measured in a simulated intraoral clinical situation using the orthodontic measurement and simulation system (OMSS). A torque of 20 degrees was applied and the correction of the misalignement was simulated experimentally with the OMSS. Each bracket/wire combination was measured five times. Maximum torquing moments and torque loss were determined. The results were analysed with one-way analysis of variance, with the bracket serving as the sole discriminating variable, and the Tukey test at the 0.05 level of significance.

The ceramic bracket (Fascination 2) presented the highest torquing moment (35 Nmm) and, together with a SS bracket, the lowest torque loss (4.6 degrees). Self-ligating, polycarbonate, and selective metallic brackets demonstrated almost a 7-fold decreased moment developed during insertion of a 0.019 x 0.022-inch SS wire into a 0.022-inch slot and a 100 per cent increase in loss.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer:
Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.