Skip Navigation

The European Journal of Orthodontics 2008 30(1):100-107; doi:10.1093/ejo/cjm094
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Wendl, B.
Right arrow Articles by Muchitsch, P.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Wendl, B.
Right arrow Articles by Muchitsch, P.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author 2008. Published by Oxford University Press on behalf of the European Orthodontic Society. All rights reserved. For permissions, please email: journals.permissions@oxfordjournals.org.

Indirect bonding—a new transfer method

B. Wendl, H. Droschl and P. Muchitsch

Department of Orthodontics and Dentofacial Orthopedics, University of Graz, Austria

Address for correspondenceDr B. wendl, Klinische Abteilung für Kieferorthopädie, Universitätszahnklinik für ZMK, Auenbruggerplatz 12, A-8036 Graz, Austria, E-mail: dr.b.wendl{at}tele2.at


   Abstract

The aim of this in vitro study was to investigate both shear bond strength (SBS) by shear testing of indirectly bonded brackets, and the accuracy of a new transfer method, the Aptus bonding device (ABD). For comparison, the SBS of directly bonded brackets in two experimental arrangements was also measured. The precision of the positioning of the indirect bracket transfer was assessed by photographic superimposition and three-dimensional (3D) measurement of the bracket positions on the working and plaster models using a 3D laser scan. Statistical analysis was carried out by means of descriptive and explorative data using the SPSS program. To compare groups, a one-factor analysis of variance and post hoc tests (Tukey-HSD) were used. The level of significance was set at P < 0.05.

SBS using indirect and direct bonding, with the same experimental arrangement and the same adhesives (Concise and Transbond), showed no significant differences. For direct bonding, using only one adhesive (Transbond), lower values were observed, but they were only statistically significant for the premolar teeth. The clinically required minimum bond strength of 6 MPa was achieved in all groups.

Superimposition of the photographs of the indirectly bonded upper labial segment brackets showed no deviations. The results of the 3D measurement of the positions of the brackets on the working and plaster models only yielded small deviations (0.15 mm along the X-axis in the centre, 0.17 mm along the Y-axis, and 0.19 mm along the Z-axis). The ABD is a useful adjunct to bond placement and does not compromise bond strength.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer:
Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.