The European Journal of Orthodontics Advance Access originally published online on August 21, 2006
The European Journal of Orthodontics 2007 29(1):1-7; doi:10.1093/ejo/cjl028
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Biomechanics of a modified Pendulum appliancetheoretical considerations and in vitro analysis of the force systems
Department of Orthodontics, Rheinisch Westfälische Technische Hochschule Aachen University, Germany
Address for correspondence Dr Gero Kinzinger, Department of Orthodontics, RWTH Aachen University, Pauwelsstrasse 30, D-52074 Aachen, Germany, E-mail: GKinzinger{at}ukaachen.de
| Abstract |
|---|
The aim of this study was to analyse the acting forces and moments induced by a special orthodontic appliance, the Pendulum K, for molar distalization in the transverse and sagittal planes.
The purpose-designed test set-up (artificial maxilla with anchorage unit and two electrothermodynamic molars, an electronic measuring unit, a unit with forcemoment sensor, an analogue/digital converter, and a data read-out unit) allowed simulation of in vivo conditions on the one hand and precise determination of the force systems on the other. The appliances investigated were three specimens of the Pendulum K.
In vitro measurement of the resulting force systems revealed that the forces and moments in the transverse and sagittal planes remained almost constant over a 3 mm measuring increment when the distal screw was continuously activated (10 activations/mm). Without reactivation of the incorporated distal screw, however, a marked decline in the force systems was recorded.
The Pendulum K allows translatory distalization of the upper molars and thus dental arch expansion, dispensing with the need for permanent teeth to be extracted, subject to a corresponding indication. This is achieved by continuous adjustment of an incorporated distal screw and by specific pre-activations of the Pendulum springs.
![]()
CiteULike
Connotea
Del.icio.us What's this?
This article has been cited by other articles:
![]() |
G. S. M. Kinzinger, M. Eren, and P. R. Diedrich Treatment effects of intraoral appliances with conventional anchorage designs for non-compliance maxillary molar distalization. A literature review Eur J Orthod, December 1, 2008; 30(6): 558 - 571. [Abstract] [Full Text] [PDF] |
||||