The inappropriateness of conventional orthodontic bond strength assessment protocols
Z Biomaterials Science Unit, University of Manchester Dental School, Manchester, UK ZZ The Ohio State University, College of Dentistry, Columbus, OH, USA
The purpose of this article is to examine the soundness of conventional orthodontic bonding assessment methods. A classification of bond strength studies is proposed with the testing environment (in vivo, in vitro, and ex vivo), loading mode (shear, tensile, and torsion), and bonding substrate (enamel, restorative, and prosthetic materials) serving as discriminating variables. Inconsistencies throughout the various stages of research protocols are analysed. These include the following: tooth selection, storage, and preparation; bonding; testing; and data analysis with regard to the clinical applicability of the reported information, as well as the scientific integrity of the testing procedure.
Contradictory models may partially account for the considerable variability noted for reported bond strength values of different orthodontic bonding systems. Such discrepancies may also explain the conflicting evidence reported on the failure characteristics of the components of the bonding system in different trials examining the efficacy of nominally identical materials.
A novel approach to study the fatigue life of materials is proposed to understand the processes occurring prior to bond failure. Mock research data manipulation is also utilized to illustrate the correct statistical treatment of findings, and recommendations for future research are made to ensure scientific soundness and clinical applicability of data.
![]()
CiteULike
Connotea
Del.icio.us What's this?
This article has been cited by other articles:
![]() |
M. Ozcan, K. Finnema, and A. Ybema Evaluation of failure characteristics and bond strength after ceramic and polycarbonate bracket debonding: effect of bracket base silanization Eur J Orthod, April 1, 2008; 30(2): 176 - 182. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Banks and B. Thiruvenkatachari Long-term clinical evaluation of bracket failure with a self-etching primer: a randomized controlled trial J. Orthod., December 1, 2007; 34(4): 243 - 251. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. R. Prietsch, A. M. Spohr, I. N. Lima da Silva, J. C. Pinheiro Beck, and H. M. Silva Oshima Development of a device to measure bracket debonding force in vivo Eur J Orthod, December 1, 2007; 29(6): 564 - 570. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. Valletta, D. Prisco, R. De Santis, L. Ambrosio, and R. Martina Evaluation of the debonding strength of orthodontic brackets using three different bonding systems Eur J Orthod, December 1, 2007; 29(6): 571 - 577. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Banks and T. V. Macfarlane Bonded versus banded first molar attachments: a randomized controlled clinical trial J. Orthod., June 1, 2007; 34(2): 128 - 136. [Abstract] [Full Text] [PDF] |
||||
![]() |
H Korbmacher, L Huck, T Adam, and B Kahl-Nieke Evaluation of an antimicrobial and fluoride-releasing self-etching primer on the shear bond strength of orthodontic brackets Eur J Orthod, October 1, 2006; 28(5): 457 - 461. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Mavropoulos, A. Karamouzos, G. Kolokithas, and A. E. Athanasiou In vivo evaluation of two new moisture-resistant orthodontic adhesive systems: a comparative clinical trial J. Orthod., June 1, 2003; 30(2): 139 - 147. [Abstract] [Full Text] [PDF] |
||||