The European Journal of Orthodontics Advance Access published online on February 20, 2009
The European Journal of Orthodontics, doi:10.1093/ejo/cjn103
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Comparison of a recently developed nanofiller self-etching primer adhesive with other self-etching primers and conventional acid etching
aran
lu Kama
Department of Orthodontics, Faculty of Dentistry, Dicle University, Diyarbak
r, Turkey
Address for correspondenceGüvenç Ba
aran, Department of Orthodontics, Faculty of Dentistry, Dicle University, 21280 Diyarbak
r, Turkey, E-mail: basaran{at}dicle.edu.tr
| Summary |
|---|
|
|
|---|
The purpose of this ex vivo study was to compare the bond strengths and modes of failure of brackets bonded with three self-etching products [Adper Prompt L-Pop (3M Espe), Futurabond NR (Voco) and Transbond Plus (3M Unitek)] and a conventional 38 per cent phosphoric acid-etching system Etch-Rite (Pulpdent Corp.) at two different time points. Ninety-six defect-free premolars were randomly allocated to eight groups (n = 12). The etching procedure was carried out according to the manufacturers instructions. The shear bond strengths (SBSs) were measured after storage in distilled water for 12 and 24 hours. The brackets were debonded using a universal testing machine with a cross-head speed of 0.5 mm/minute. Multiple comparisons of the SBSs for the different etching types were performed using analysis of variance. The chi-square test was used to evaluate differences in adhesive remnant index (CARI) scores among the groups.
The differences between SBSs analysed at 12 and 24 hours were not significantly different. Although a significant difference (P < 0.01) was observed with conventional and self-etching primer (SEP) adhesive systems, SEP revealed bond strengths higher than clinically accepted limits (6–8 MPa). SEP systems can achieve successful orthodontic bond strengths. The rate of development of the bond strength must be determined to ensure sufficient maturation of orthodontic adhesives before functional loading.
| Introduction |
|---|
|
|
|---|
Since the report by Buonocore (1955)
Advances in adhesive technology have led orthodontists to incorporate new adhesives, composite resins, and bonding techniques into clinical practice. Self-etching primer (SEP) products, which combine acid and primer, simplify the bonding procedure, reduce chair time, and avoid the side-effects of acid etching (Büyükyilmaz et al., 2003
; Grubisa et al., 2004
; Sirirungrojying et al., 2004
).
The efficacy of SEPs regarding adhesion to enamel has been studied; although clinically acceptable, lower values for shear bond strength (SBS) were reported when compared with conventional multistep etch and prime systems (Silverstone et al., 1975
; Mandall et al., 2002
).
In a clinical situation, bond failure can occur soon after the orthodontic bracket is positioned as a result of stress (Katona, 1997
; Knox et al., 2001
). This could be caused by the orthodontic procedure, contraction of the adhesive, or normal oral functions such as mastication. Sufficient bond strength is a factor that contributes to the clinical success of orthodontic treatment, and data collected after 24 hours have generally been used to measure the bond strengths of orthodontic adhesives (Fox et al., 1994
; Stanford et al., 1997
). Previous reports have highlighted the importance of the early bond strength of orthodontic adhesives and shown that materials exposed to the oral environment must be strong enough to withstand both short- and long-term forces (Whitlock et al., 1994
; Mitchell et al., 1995
; Trites et al., 2004
). Some previous studies focused on the immediate bond strength achieved by adhesive systems, by measurement at selected time intervals over a 24 hour period (Bin Abdullah and Rock, 1996
; Chamda and Stein, 1996
)
Recent advances in bonding systems have lead to the use of nanotechnology in dentistry. Futurabond NR (Voco, Cuxhaven, Germany) is a new dentine–enamel bond reinforced with nanofillers. The manufacturer claims that this self-etching adhesive is suitable for all light-curing restorative procedures.
This ex vivo study aimed to determine and compare the SBSs and mode of failure of brackets bonded with (1) a recently developed modification of the self-etching adhesive system; (2) a fluoride-releasing, self-etching adhesive system; (3) a newly developed nano-reinforced self-etching adhesive system; and (4) a conventional 38 per cent phosphoric acid etching system. A further aim was to determine if there was a significant difference in SBSs between these four etching systems related to time by comparing them at 12 and 24 hours.
| Materials and methods |
|---|
|
|
|---|
A total of 96 human premolars were used in this study. After extraction, the teeth were stored in 0.9 per cent NaCl solution at 4°C. The criteria for tooth selection included intact buccal enamel with no cracks caused by the extraction forceps and no caries. After extraction, all enamel surfaces were examined under a light stereomicroscope (S240, Olympus, Tokyo, Japan) at x10 magnification. The teeth were assigned to eight groups each of 12 specimens using random number tables (Figure 1). The teeth were cleansed of soft tissue, embedded in cold-curing, fast-setting acrylic (Leocryl, Leone, Sesto Fiorentino, Italy), and placed in a plastic box. Each tooth was orientated so that its labial surface was parallel to the applied force during shear bond testing.
|
The orthodontic etching systems used in this study were Adper Prompt L-Pop self-etch adhesive (3M Espe, St Paul, Minnesota, USA), nano-reinforced Futurabond NR single dose (Voco), Transbond Plus SEP (3M Unitek, Monrovia, California, USA), and Etch-Rite (Pulpdent Corp., Watertown, Massachusetts, USA) 38 per cent phosphoric acid. All orthodontic etching systems were used according to the manufacturers instructions. For the phosphoric acid group, the original primer of the Transbond XT adhesive was used.
After etching, stainless steel standard edgewise premolar brackets (GAC, Central Islip, New York, USA) were bonded to the teeth with a surface bonding area of 12.6 mm2. A thin, uniform coating of adhesive agent was applied to the etched surface. After application of Transbond XT, the bracket was placed onto the tooth surface, adjusted to its final position, and pressed firmly into place. Excess sealant and adhesive were removed from the periphery of the bracket base with a probe to ensure a uniform bonding area. Light curing was performed for a total of 40 seconds by irradiating the mesial, distal, occlusal, and gingival aspects of the tooth for 10 seconds each.
Another important point in testing the ex vivo SBS of adhesives is the light consistency and intensity. The device (Hilux LED Max, Benlioglu Dental Inc., Ankara, Turkey) used in the study had an internal light metre and between each curing episode, the device was tested for intensity (Figure 2).
|
After bonding, the specimens were transferred to distilled water at 37°C and stored for 12 and 24 hours. SBS testing was accomplished with a chisel edge mounted on the cross-head of a testing machine (Instron Testometric M500–25 KN, Testometric Company Ltd, Rochdale, Lancashire, UK). The chisel edge contacted at the bracket and enamel interface at a crosshead speed of 0.5 mm/minute; the force decay was recorded in Newtons and then converted to megapascals by dividing the force by the bracket base area. All tests were conducted at 24 ± 2°C.
After debonding, the brackets were examined under x10 magnification to evaluate the amount of resin remaining on the tooth. The adhesive remnant index (ARI) was used to describe the quantity of resin remaining on the tooth surface (Årtun and Bergland, 1984
).
Descriptive statistics, including the mean, standard deviation, and minimum and maximum values, were calculated for each group. Multiple comparisons of SBSs for the different etching types were performed using analysis of variance. The chi-square test was used to evaluate differences in ARI scores among the groups. All statistical evaluations were made using the Statistical Package for Social Sciences (Windows, release 10.0.0, SPSS Inc., Chicago, Illinois, USA).
| Results |
|---|
|
|
|---|
Shear bond strengths
Descriptive statistics for the comparison of SBS and ARI scores for the four groups are given in Tables 1–3![]()
. Table 1 shows the observed SBS at 12 and 24 hours. Although SBS at 24 hours was generally higher than that observed at 12 hours, there was no statistically significant difference at either time point. The mean SBS achieved with the conventional acid etch system was statistically significantly greater (P < 0.01) than that observed with the SEP adhesive systems. There was no statistically significant difference in bond strength between the SEP adhesive systems.
|
|
|
Because there was no statistical significance of time on SBS, the 12 and 24 hour groups were combined (Table 2). Again, there was no statistically significant difference between the SEP adhesive systems but a significant difference was observed when compared with the conventional acid-etching system (P < 0.01).
ARI scores
The ARI scores (Table 3) indicate the site of bond failure for the acid- and self-etched groups at the 12 and 24 hour debonding times. The scores were not statistically different from each other when time and adhesive system were considered as the variables. A slight tendency towards a score of 3 was noted with debonding at 24 hours but this was not statistically significant. Similarly, ARI scores achieved with conventional acid-etching systems had a slight tendency towards a score of 3, indicating that more adhesive was left on the enamel surface.
| Discussion |
|---|
|
|
|---|
Although clinical orthodontic procedures have improved, there is still a need to enhance adhesive systems to shorten bonding procedures and eliminate enamel loss without jeopardizing clinical performance. This has led manufacturers to develop SEP adhesive systems, to reduce the steps required, and to decrease chair-side time and technique sensitivity (Büyükyilmaz et al., 2003
In general, SEPs are considered as bicomponent hydrophilic adhesives containing hydrofluoric complexes, deionized water, stabilizer in one compartment and activator, orthophosphoric ester methyacrylate, and stabilizers in a separate compartment (Bishara et al., 2002
; Velo et al., 2002
). The acidic monomer becomes neutralized when it is applied to the enamel surface. The pH is raised and demineralization occurs as a result of recruited calcium ions from the hydroxyapatite crystals. The encapsulated ions in the primer provide infiltration of the adhesive for micromechanical adhesion of the resin (Bishara et al., 1999
; Brosnihan and Safranek, 2000
; Bishara et al., 2002
; Velo et al., 2002
; Büyükyilmaz et al., 2003
; Grubisa et al., 2004
). According to the manufacturer of Futurabond NR, nanoparticles acting as cross links reinforce the bond and hybrid layer. The manufacturer claims that the minute size of the nanofillers allows complete penetration which contributes to high adhesion. However, this was not supported by the results of this study. If the manufacturers claims were valid, the SBS of the nanofilled material would have been higher than that of the other adhesives; yet the observed mean SBS of Futurabond NR (7.9 ± 2.5 MPa) was the lowest of all four adhesives, although there was no statistically significant difference among the SEP adhesive systems. Fillers are added to the adhesives to provide strengthening, increase stiffness, and reduce dimensional changes (Ferracane et al., 1987
; Kim et al., 1994
). Previous studies (Miyazaki et al., 1991
; James et al., 2003
; Faltermeier et al., 2007
) demonstrated that the filler content influences polymerization shrinkage. In the light of these findings, it is suggested that smaller filler particles lead to greater shrinkage which results in low bond strengths, which was observed with Futurabond NR.
All SEP adhesive systems (Adper Prompt L-Pop, 8.3 ± 2.4 MPa; Transbond Plus, 9.7 ± 2.6 MPa; Futurabond NR, 7.9 ± 2.5 MPa) had statistically significantly lower mean SBS values than the conventional acid etch system (14.4 ± 2.2 MPa). Reynolds (1975)
reported that bond strengths of 6–8 MPa were clinically acceptable. The observed mean SBSs with the SEP adhesive systems were approximately consistent with the upper limit of this range and were similar to those found by Arnold et al. (2002)
.
The reason for using SEP adhesives (Adper Prompt L-Pop and Transbond Plus) in this study was not to justify their suitability for orthodontic bonding since this recommendation is evident from previous studies (Bishara et al., 1999
; Brosnihan and Safranek, 2000
; Velo et al., 2002
; Büyükyilmaz et al., 2003
; Grubisa et al., 2004
; Sirirungrojying et al., 2004
) but to compare the recently developed nanofiller with other SEP adhesives in addition to a conventional acid-etching adhesive system.
Adequate bond strength is a factor that contributes to the clinical success of orthodontic treatment. Data collected after 24 hours have generally been used to measure the bond strengths of orthodontic adhesives (Fox et al., 1994
; Yamamoto et al., 2006
). The earliest time point at which there was no significant difference in bond strength compared with that at 24 hours was defined as the initial stable time. In the present study, the aim was to determine if a stable bond strength was reached at 12 hours or if it continued to increase up to 24 hours. Although there was no statistically significant difference between bond strengths at either time point, generally the bond strengths at 24 hours tended to be higher. Adper Prompt L-Pop showed values of 8.1 ± 2.4 and 8.4 ± 2.5 MPa, Transbond Plus 9.2 ± 2.4 and 10.2 ± 2.8 MPa, and Futurabond NR 7.4 ± 2.6 and 8.6 ± 2.6 MPa at 12 and 24 hours, respectively. Conventional acid etching revealed a higher mean bond strength than all SEP adhesives at 12 (13.2 ± 1.9 MPa) and 24 (15.6 ± 2.6 MPa) hours.
There was no statistically significant difference in ARI scores at 12 or 24 hours. All adhesives showed higher scores with debonding at 24 hours, i.e. more adhesive was left on the enamel surface. This could be considered to be either an advantage or a disadvantage. While less chair time is needed with less adhesive left on enamel after debonding, there is an inverse risk of enamel fracture while debonding.
| Conclusion |
|---|
|
|
|---|
All adhesives tested achieved clinically acceptable bond strengths. Although an adequate bond strength is reached at 12 hours, all adhesives continue strengthen up to 24 hours.
| References |
|---|
|
|
|---|
-
Arnold RW, Combe EC, Warford JH. Bonding of stainless steel brackets to enamel with a new self-etching primer. American Journal of Orthodontics and Dentofacial Orthopedics (2002) 122:274–276.[CrossRef][Web of Science][Medline]
Årtun J, Bergland S. Clinical trials with crystal growth conditioning as an alternative to acid-etch enamel pretreatment. American Journal of Orthodontics (1984) 85:333–340.[CrossRef][Web of Science][Medline]
Bin Abdullah M, Rock WP. The effect of etch time and debond interval upon the shear bond strength of metallic orthodontic brackets. British Journal of Orthodontics (1996) 23:121–124.[Abstract]
Bishara SE, Gordon VV, VonWald L, Jakobsen JR. Shear bond strength of composite, glass ionomer and acidic primer adhesive systems. American Journal of Orthodontics and Dentofacial Orthopedics (1999) 115:24–28.[CrossRef][Web of Science][Medline]
Bishara SE, Ajlouni R, Laffoon JF, Warren JJ. Effect of a fluoride-releasing self-etch acidic primer on the shear bond strength of orthodontic brackets. Angle Orthodontist (2002) 72:199–202.[Web of Science][Medline]
Brosnihan J, Safranek L. Orthodontic bonding: the next generation. Journal of Clinical Orthodontics (2000) 10:614–616.
Buonocore MG. A simple method of increasing the adhesion of acrylic filling materials to enamel surfaces. Journal of Dental Research (1955) 34:849–853.
Büyükyilmaz T, Usumez S, Karaman AI. Effect of self-etching primers on bond strength—are they reliable? Angle Orthodontist (2003) 73:64–70.[Web of Science][Medline]
Chamda RA, Stein E. Time-related bond strengths of light-cured and chemically cured bonding systems: an in vitro study. American Journal of Orthodontics and Dentofacial Orthopedics (1996) 110:378–382.[CrossRef][Web of Science][Medline]
Faltermeier A, Rosentritt M, Faltermeier R, Reicheneder C, Müβig D. Influence of filler level on the bond strength of orthodontic adhesives. Angle Orthodontist (2007) 77:494–498.[CrossRef][Web of Science][Medline]
Ferracane JL, Antonio RC, Matsumoto H. Variables affecting the fracture toughness of dental composites. Journal of Dental Research (1987) 66:1140–1145.
Fox NA, McCabe JF, Buckley JG. A critique of bond strength testing in orthodontics. British Journal of Orthodontics (1994) 21:33–43.[Abstract]
Grubisa HS, Heo G, Raboud D, Glover KE, Major PW. An evaluation and comparison of orthodontic bracket bond strengths achieved with self-etching primer. American Journal of Orthodontics and Dentofacial Orthopedics (2004) 126:213–219.[CrossRef][Web of Science][Medline]
James JW, Miller BH, English JD, Tadlock LP, Buschang PH. Effects of high-speed curing devices on shear bond strength and microleakage of orthodontic brackets. American Journal of Orthodontics and Dentofacial Orthopedics (2003) 123:555–561.[CrossRef][Web of Science][Medline]
Katona TR. Stresses developed during clinical debonding of stainless steel orthodontic brackets. Angle Orthodontist (1997) 67:39–46.[Web of Science][Medline]
Kim KH, Park JH, Imai Y, Kishi T. Microfracture mechanisms of dental resin composites containing spherically-shaped filler particles. Journal of Dental Research (1994) 73:499–504.
Knox J, Kralj B, Hübsch PF, Middleton J, Jones ML. An evaluation of the influence of orthodontic adhesive on the stresses generated in a bonded bracket finite element model. American Journal of Orthodontics and Dentofacial Orthopedics (2001) 119:43–53.[CrossRef][Web of Science][Medline]
Mandall NA, Millett DT, Mattick CR, Hickman J, Worthington HV, Macfarlane TV. Orthodontic adhesives: a systematic review. Journal of Orthodontics (2002) 29:205–210.
Mitchell CA, OHagan E, Walker JM. Probability of failure of orthodontic brackets bonded with different cementing agents. Dental Materials (1995) 11:317–322.[CrossRef][Web of Science][Medline]
Miyazaki M, Hinoura K, Onose H, Moore BK. Effect of filler content of light-cured composites on bond strength to bovine dentine. Journal of Dentistry (1991) 19:301–303.[CrossRef][Web of Science][Medline]
Powers JM, Kim HB, Turner DS. Orthodontic adhesives and bond strength testing. Seminars in Orthodontics (1997) 3:147–156.[CrossRef][Medline]
Reynolds IR. A review of direct orthodontic bonding. British Journal of Orthodontics (1975) 2:171–178.
Sakaki T, Fukushima T, Kawai S, Matsumoto M. Effect of physical properties of direct bonding adhesives on bonding to etched enamel. Journal of Prosthetic Dentistry (1994) 71:552–559.[CrossRef][Web of Science][Medline]
Silverstone LM, Saxton CA, Dogan IL, Fejerskov O. Variation in the pattern of acid etching on human dental enamel examined by scanning electron microscopy. Caries Research (1975) 9:373–387.[Web of Science][Medline]
Sirirungrojying S, Saito K, Hayakawa T, Kasai K. Efficacy of using self-etching primer with a 4-META/MMA-TBB resin cement in bonding orthodontic brackets to human enamel and effect of saliva contamination on shear bond strength. Angle Orthodontist (2004) 74:251–258.[Web of Science][Medline]
Stanford SK, Wozniak WT, Fan PL. The need for standardization of test protocols. Seminars in Orthodontics (1997) 3:206–209.[CrossRef][Medline]
Trites B, Foley TF, Banting D. Bond strength comparison of 2 self-etching primers over a 3-month storage period. American Journal of Orthodontics and Dentofacial Orthopedics (2004) 126:709–716.[CrossRef][Web of Science][Medline]
Velo S, Carano A, Carano A. Self-etching vs. traditional bonding systems in orthodontics: an in vitro study. Orthodontics and Craniofacial Research (2002) 5:166–169.[CrossRef]
Whitlock BO, Eick JD, Ackerman RJ, Glaros AG, Chappell RP. Shear strength of ceramic brackets bonded to porcelain. American Journal of Orthodontics and Dentofacial Orthopedics (1994) 106:358–364.[Web of Science][Medline]
Yamamoto A, Yoshida T, Tsubota K, Takamizawa T, Kurokawa H, Miyazaki M. Orthodontic bracket bonding: enamel bond strength vs time. American Journal of Orthodontics and Dentofacial Orthopedics (2006) 130:435–441.
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||

