The European Journal of Orthodontics Advance Access published online on July 9, 2008
The European Journal of Orthodontics, doi:10.1093/ejo/cjn022
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Influence of different brazing and welding methods on tensile strength and microhardness of orthodontic stainless steel wire
* Department of Orthodontics
** Institute of Physics and Solid State Mechanics
*** Department of Operative Dentistry and Periodontology, Martin-Luther-University Halle-Wittenberg, Germany
Address for correspondenceDr J. J. Bock Department of Orthodontics University School of Dental Medicine Martin-Luther-University Halle-Wittenberg Grosse Steinstrasse 19 06097 Halle/Saale Germany E-mail: drbock{at}web.de
| Summary |
|---|
|
|
|---|
The aim of this study was to compare the mechanical strength and microhardness of joints made by conventional brazing and tungsten inert gas (TIG) and laser welding. A standardized end-to-end joint configuration of the orthodontic wire material in spring hard quality was used. The joints were made using five different methods: brazing (soldering > 450°C) with universal silver solder, two TIG, and two laser welders. Laser parameters and welding conditions were used according to the manufacturers guidance. The tensile strengths were measured with a universal testing machine (Zwick 005). The microhardness measurements were carried out with a hardness tester (Zwick 3202). Data were analysed using one-way analysis of variance and Bonferroni's post hoc correction (P < 0.05).
In all cases, brazing joints ruptured at low levels of tensile strength (198 ± 146 MPa). Significant differences (P < 0.001) between brazing and TIG or laser welding were found. The highest means were observed for TIG welding (699–754 MPa). Laser welding showed a significantly lower mean tensile strength (369–520 MPa) compared with TIG welding. Significant differences (P < 0.001) were found between the original orthodontic wire and the mean microhardness at the centre of the welded area. The mean microhardness differed significantly between brazing (1.99 GPa), TIG (2.22–2.39 GPa) and laser welding (2.21–2.68 GPa).
For orthodontic purposes, laser and TIG welding are solder-free alternatives to joining metal. TIG welding with a lower investment cost is comparable with laser welding. However, while expensive, the laser technique is a sophisticated and simple method.
| Introduction |
|---|
|
|
|---|
The joining of a metal framework is frequently necessary to create individual orthodontic appliances and to achieve efficient treatment procedures. Brazing, defined as soldering at a temperature of more than 450°C, is the conventional method of joining orthodontic wires in different clinical situations (Gulker et al., 1994
Another method employed for joining metal frameworks is laser welding (Berg et al., 1995
; Tambasco et al., 1996
; Chai and Chou, 1998
; Taylor et al., 1998
; Wang and Chang, 1998
; Baba et al., 2004
; Krishnan and Kumar, 2004
; Baba and Watanabe 2005
; Uysal et al., 2005
; Verstrynge et al., 2006
). To weld dental alloys, crystals of yttrium, aluminium, and garnet with added neodymium are mainly used to emit laser beams (Yamagishi et al., 1993
; Liu et al., 2002
; Iwasaki et al., 2004
; Watanabe and Topham, 2004
, 2006
; Srimaneepong et al., 2005
; Watanabe et al., 2006
).
In 2005, an alternative with lower investment costs was introduced in orthodontics. Based on the well-known tungsten inert gas (TIG) welding, two different devices for orthodontic purposes were developed (Rocha et al., 2006
). The welding heat is produced by a light bow between tungsten anode and metal. The advantages of laser and TIG welding systems can be summarized as follows: no solder and thus no galvanic corrosion at the joint, small focus, a stereomicroscope for efficient working and an argon-shielding atmosphere to prevent the oxidation around the welding zone (Jelmert et al., 1995
; Solmi et al., 2004
; Sestini et al., 2006
).
Therefore, the aim of this study was to compare the mechanical strength and the microhardness of joints made using conventional brazing and TIG and laser welding.
| Materials and methods |
|---|
|
|
|---|
A standardized end-to-end joint configuration of the orthodontic wire (Forestanit Lot: 272; Forastadent, Pforzheim, Germany) in spring hard quality (diameter 1.2 mm) was used. The joints were made using five different methods: brazing with universal silver solder, OrthoPhaser (Dentaurum, Ispringen, Germany), Welder (Schütz Dental, Rosbach, Germany), DL 2002 (Dentaurum), and LWI (Schütz Dental). Laser parameters and welding conditions were used in accordance with the manufacturers specifications (Table 1). Two different laser and TIG welding parameters of the devices made by Schütz Dental were tested. For each joining method, 10 specimens were produced.
|
The tensile strength measurement of different welding and brazing methods was carried out using a universal testing machine (Zwick 005, Zwick GmbH & Co. KG, Ulm, Germany). The wire length between the crossheads of the machine was set to a level of 5 mm. The full-scale load was set at 2000 N with a crosshead speed of 10 mm/minute.
The microhardness measurements were carried out with a hardness tester Zwick 3202 with a diamond indenter after Vickers. All measurements were conducted with a test load of 100 mN, an impact speed of 4 mm/minute and a loading period of 15 seconds. The evaluation took place via light–optical measurement of the diagonal length.
The data were analysed using the Statistical Software Package for Social Sciences (SPSS Inc., Chicago, Illinois, USA) version 12.0 and the use of one-way analysis of variance (ANOVA) and Bonferroni's post hoc test. The level of significance was set at 5 per cent.
| Results |
|---|
|
|
|---|
Means, minimum, maximum, and standard deviations (SDs) of the tensile strength of the different joining methods were calculated and are summarized in Table 2. The mean tensile strength of the original orthodontic wire (1493 ± 39 MPa) was found to be in agreement with the manufacturers specifications. Compared with these findings, welding and brazing significantly decreased the tensile strength (ANOVA, P < 0.001, Table 2). The highest means were observed for TIG welding (699–754 MPa) with low SDs. No significant differences were found between the welding devices and welding parameters (Bonferroni's post hoc test, P > 0.05, Table 2).
|
Laser welding showed a significantly lower mean tensile strength (369–520 MPa) compared with TIG welding (Bonferroni's post hoc test, P < 0.05, Table 2). No significant differences were found between the laser welding groups.
Brazing demonstrated the lowest mean tensile strength (198 ± 146 MPa) with a high SD. The tensile strength of seven specimens was lower than 350 MPa.
The mean microhardness of the Forestanit wire (spring hard quality) was measured at 3.79 ± 0.09 GPa (Figure 1a–c). In the heat-affected zone adjacent to the welding or brazing area, the wire showed a slight increase in hardness (up to 4.68 GPa, Figure 1a–c). In the joining area, the microhardness decreased (up to 1.47 GPa, Figure 1a–c). The lowest mean microhardness was found with brazing (1.99 ± 0.30 GPa) and the highest level with laser welding (Laser 2: 2.68 ± 0.14 GPa; Table 3).
|
Generally, significant differences were found between the original orthodontic wire and the mean microhardness at the centre of the joining area (ANOVA, P < 0.001). The mean microhardness significantly differed between brazing and TIG or laser welding (Bonferroni's post hoc test, P < 0.05; Table 3).
| Discussion |
|---|
|
|
|---|
Recently, Solmi et al. (2004)
Studies concerning the mechanical and microhardness characteristics of welded or soldered orthodontic wires are rare making direct comparison of different brazing and welding methods difficult. The results of tensile strength measurements of welded precious and non-precious cast alloys used in fixed or removable prosthodontics can be transferred for orthodontic purposes, but with limitations (Gawlik et al., 1996
; Mockers et al., 2002
; Krishnan and Kumar, 2004
).
The influence of brazing or welding on tensile strength has not been uniformly determined. In different studies, the factors affecting the mechanical strength of welded joints have been described: wavelength, peak pulse power, pulse energy, output energy, pulse duration, pulse frequency, and spot diameter of the laser welding machine and the type of metal used (McCartney and Doud, 1993
; Yamagishi et al., 1993
; Taylor et al., 1998
; Watanabe et al., 2001
, 2003
, 2004
, 2006
; Yan and Yang, 2006
). Chai and Chou (1998)
showed an equal or superior (range 374–562 MPa) mechanical strength of the welded sites compared with the unsectioned parent metal (540 ± 11 MPa) of different Ti alloys depending on welding conditions. In contrast, the fracture load of unwelded Ti, gold, or Co–Cr alloys in different configurations of laser welding was not achieved (Watanabe et al., 2001
, 2003
, 2004
, 2006
). Especially for gold and Co–Cr alloys, only 50 per cent or less of the original measurements were found. In the study by Bertrand et al. (2004)
, a small change in the chemical composition of the Ni-based alloys caused an important difference in weldability.
Rocha et al. (2006)
compared laser and TIG welding of non-precious alloys. TIG welding increased the flexural strength of Ti, Co–Cr, and Ni–Cr as the used welded cylinders presented higher flexural strength than the non-weld cylinders. The highest means were observed for Co–Cr weld by TIG (2665 ± 281 MPa) and non-welded Co–Cr (2654 ± 64 MPa; Rocha et al., 2006
). By contrast, laser welding (464 ± 70 MPa) achieved only 17.5 per cent of the flexural strength of Co–Cr alloy. When joining Co–Cr alloy specimens, Zupancic et al. (2006)
showed significant differences between brazing (792 MPa) and laser welding (405 MPa). Those authors estimated a low penetration depth, peripheral overheating, porosities, and carbon content of the alloy as possible reasons for the relative weakness of laser welding.
The evaluation of three orthodontic arch wire alloy materials, stainless steel, beta titanium, and Timolium, for their laser-weld characteristics showed significantly different tensile strength values between these materials (stainless steel 363 ± 22 MPa, beta titanium 463 ± 27 MPa, and Timolium 344 ± 25 MPa; Krishnan and Kumar, 2004
). Although a comparison with original wires was not carried out in that study, it could be assumed that laser-welded specimens showed a significantly lower tensile strength than pure metals (approximately 1500–1800 MPa).
The influence of used orthodontic wire material in the case of brazing was examined in the study by Dua and Nandlal (2004)
. The mean tensile strength values of soldered joints for various wire groups differed significantly. Gloria (stainless steel) wire had a lower tensile strength compared with Remanium (stainless steel) and Remaloy (Co–Cr) orthodontic wires.
In the present investigation, a direct comparison between brazing and TIG and laser welding was realized for the first time. Brazing demonstrated the lowest mean tensile strength with 70 per cent of the specimens not fulfilling the minimum of 350 MPa. TIG and laser welding showed significantly higher mean values for tensile strength, but the tensile strength of the original wire was not achievable. Therefore, welding changed the material attributes, and the loss of spring hard quality has to be considered in planning orthodontic treatment.
Determination of the microhardness of the Ni–Cr–Mo and Co–Cr–Mo alloys showed that the central part of the weld had a higher hardness (Remanium CS 340 ± 30 GPa) than the cast metal (220 ± 20 GPa). Similar results for titanium were reported by Uysal et al. (2005)
. Other authors pointed out that this was probably due to the refining in the grain size and the substructure which appears during the rapid solidification stage (Bertrand et al., 2004
; Zupancic et al., 2006
). Furthermore, while testing orthodontic wire materials using brazing and laser and TIG welding, a completely different behaviour in microhardness could be observed in the present investigation. Comparable studies were not available. The microhardness of the original wire was in the same range as that reported by Verstrynge et al. (2006)
. In laser welding, a slight tendency for a correlation between a higher mean microhardness and higher tensile strength was observed.
| Conclusion |
|---|
|
|
|---|
Tensile strength and microhardness of TIG welding is comparable with laser welding and is a low cost and solder-free alternative for orthodontic purposes.
Small changes in TIG or laser welding parameters significantly influenced the mechanical properties of orthodontic wires. Further investigations are needed to determine the optimal welding parameters for each of the devices and different joining methods.
|
| References |
|---|
|
|
|---|
-
Anselm Wiskott HW, Doumas T, Scherrer SS, Belser UC, Susz C. Mechanical and structural characteristics of commercially pure grade 2 Ti welds and solder joints. Journal of Materials Science: Materials in Medicine (2001) 12:719–725.[CrossRef][Web of Science][Medline]
Baba N, Watanabe I. Penetration depth into dental casting alloys by Nd:YAG laser. Journal of Biomedical Material Research Part B, Applied Biomaterials (2005) 72:64–68.
Baba N, Watanabe I, Liu J, Atsuta M. Mechanical strength of laser-welded cobalt-chromium alloy. Journal of Biomedical Material Research Part B, Applied Biomaterials (2004) 69:121–124.
Berg E, Wagnere WC, Davik G, Dootz ER. Mechanical properties of laser-welded cast and wrought titanium. Journal of Prosthetic Dentistry (1995) 74:250–257.[CrossRef][Web of Science][Medline]
Bertrand C, le Petitcorps Y, Albingre L, Dupuis V. Optimization of operator and physical parameters for laser welding of dental materials. British Dental Journal (2004) 196:413–418.[CrossRef][Web of Science][Medline]
Chai T, Chou CK. Mechanical properties of laser-welded cast titanium joints under different conditions. Journal of Prosthetic Dentistry (1998) 79:477–483.[CrossRef][Web of Science][Medline]
Chaves M, Vermilyea SG, Papazoglou E, Brantley WA. Effects of three soldering techniques on the strength of high-palladium alloy solder joints. Journal of Prosthetic Dentistry (1998) 79:677–684.[CrossRef][Web of Science][Medline]
Dua R, Nandlal B. A comparative evaluation of the tensile strength of silver soldered joints of stainless steel and cobalt chromium orthodontic wires with band material—an in vitro study. Journal of the Indian Society of Pedodontics and Preventive Dentistry (2004) 22:13–16.[Medline]
Gawlik JA, Mathieu GP, Hondrum S. The effects of tack welding and increasing surface area on the tensile strength of silver electric and flame soldered stainless steel joints. Pediatric Dentistry (1996) 18:215–218.[Medline]
Gulker IA, Martini RT, Zinner ID, Panno FV. A comparison of hydrogen/oxygen and natural gas/oxygen torch soldering techniques. International Journal of Prosthodontics (1994) 7:258–263.[Medline]
Heidemann J, Witt E, Feeg M, Werz R, Pieger K. Orthodontic soldering techniques: aspects of quality assurance in the dental laboratory. Journal of Orofacial Orthopedics (2002) 63:325–338.[CrossRef][Medline]
Iwasaki K, Ohkawa S, Rosca ID, Uo M, Akasaka T, Watari F. Distortion of laser welded titanium plates. Dental Materials Journal (2004) 23:593–599.[Web of Science][Medline]
Jelmert O, Hansteen IL, Langard S. Cytogenetic studies of stainless steel welders using the tungsten inert gas and metal inert gas methods for welding. Mutation Research (1995) 342:77–85.[CrossRef][Web of Science][Medline]
Krishnan V, Kumar KJ. Weld characteristics of orthodontic archwire materials. Angle Orthodontist (2004) 74:533–538.[Web of Science][Medline]
Liu J, Watanabe I, Yoshida K, Atsuta M. Joint strength of laser-welded titanium. Dental Materials (2002) 18:143–148.[CrossRef][Web of Science][Medline]
McCartney JW, Doud R. Passive adaptation of the prosthesis-implant interface by soldering gold cylinders to the framework casting. Journal of Prosthetic Dentistry (1993) 70:17–20.[CrossRef][Web of Science][Medline]
Mockers O, Deroze D, Camps J. Cytotoxicity of orthodontic bands, brackets and archwires in vitro. Dental Materials (2002) 18:311–317.[CrossRef][Web of Science][Medline]
Oda Y, Okabe T. Effect of corrosion on the strength of soldered titanium and Ti-6Al-4V alloy. Dental Materials (1996) 12:167–172.[CrossRef][Web of Science][Medline]
Rocha R, Pinheiro AL, Villaverde AB. Flexural strength of pure Ti, Ni-Cr and Co-Cr alloys submitted to Nd:YAG laser or TIG welding. Brazilian Dental Journal (2006) 17:20–23.[Medline]
Scroggs MW, Lewis JS, Proia AD. Corneal argyrosis associated with silver soldering. Cornea (1992) 11:264–269.[Web of Science][Medline]
Sestini S, et al. In vitro toxicity evaluation of silver soldering, electrical resistance, and laser welding of orthodontic wires. European Journal of Orthodontics (2006) 28:567–572.
Solmi R, et al. Interactions of fibroblasts with soldered and laser-welded joints. Biomaterials (2004) 25:735–740.[CrossRef][Web of Science][Medline]
Srimaneepong V, Yoneyama T, Kobayashi E, Doi H, Hanawa T. Mechanical strength and microstructure of laser-welded Ti-6Al-7Nb alloy castings. Dental Materials Journal (2005) 24:541–549.[Web of Science][Medline]
Tambasco J, Anthony T, Sandven O. Laser welding in the dental laboratory: an alternative to soldering. Journal of Dental Technology (1996) 13:23–31.
Taylor JC, Hondrum SO, Prasad A, Brodersen CA. Effects of joint configuration for the arc welding of cast Ti-6Al-4V alloy rods in argon. Journal of Prosthetic Dentistry (1998) 79:291–297.[CrossRef][Web of Science][Medline]
Uysal H, Kurtoglu C, Gurbuz R, Tutuncu N. Structure and mechanical properties of Cresco-Ti laser-welded joints and stress analyses using finite element models of fixed distal extension and fixed partial prosthetic designs. Journal of Prosthetic Dentistry (2005) 93:235–244.[CrossRef][Web of Science][Medline]
Verstrynge A, Van Humbeeck J, Willems G. In vitro evaluation of the material characteristics of stainless steel and beta-titanium orthodontic wires. American Journal of Orthodontics and Dentofacial Orthopedics (2006) 130:460–470.[CrossRef][Web of Science][Medline]
Wang RR, Chang CT. Thermal modeling of laser welding for titanium dental restorations. Journal of Prosthetic Dentistry (1998) 79:335–341.[CrossRef][Web of Science][Medline]
Watanabe I, Topham DS. Tensile strength and elongation of laser-welded Ti and Ti-6AL-7NB. Journal of Biomedical Materials Research Part B, Applied Biomaterials (2004) 71:46–51.
Watanabe I, Topham DS. Laser welding of cast titanium and dental alloys using argon shielding. Journal of Prosthodontics (2006) 15:102–107.[CrossRef][Medline]
Watanabe I, Liu J, Atsuta M. Effects of heat treatments on mechanical strength of laser-welded equi-atomic AuCu-6at%Ga alloy. Journal of Dental Research (2001) 80:1813–1817.
Watanabe I, Baba N, Chang J, Chiu Y. Nd:YAG laser penetration into cast titanium and gold alloy with different surface preparations. Journal of Oral Rehabilitation (2006) 33:443–446.[CrossRef][Web of Science][Medline]
Watanabe I, Liu J, Atsuta M, Okabe T. Effect of welding method on joint strength of laser-welded gold alloy. American Journal of Dentistry (2003) 16:231–234.[Web of Science][Medline]
Watanabe I, Liu J, Baba N, Atsuta M, Okabe T. Optimizing mechanical properties of laser-welded gold alloy through heat treatment. Dental Materials (2004) 20:630–634.[CrossRef][Web of Science][Medline]
Yamagishi T, Ito M, Fujimura Y. Mechanical properties of laser welds of titanium in dentistry by pulsed Nd:YAG laser apparatus. Journal of Prosthetic Dentistry (1993) 70:264–273.[CrossRef][Web of Science][Medline]
Yan XJ, Yang DZ. Corrosion resistance of a laser spot-welded joint of NiTi wire in simulated human body fluids. Journal of Biomedical Materials Research Part A (2006) 77:97–102.[Medline]
Yokota K, Minami T, Michitsuji H, Fujio T, Yamada S. Occupational dermatitis from soldering flux. Indian Health (2004) 42:383–384.[CrossRef]
Zupancic R, Legat A, Funduk N. Tensile strength and corrosion resistance of brazed and laser-welded cobalt-chromium alloy joints. Journal of Prosthetic Dentistry (2006) 96:273–282.[CrossRef][Web of Science][Medline]
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||