The European Journal of Orthodontics Advance Access published online on October 18, 2007
The European Journal of Orthodontics, doi:10.1093/ejo/cjm061
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Three-dimensional analysis of orthodontic tooth movement based on XYZ and finite helical axis systems
* Department of Orthodontics, School of Dentistry, Health Sciences University of Hokkaido, Japan
** Department of Oral Anatomy, College of Dentistry, Seoul National University, Korea
Address for correspondence, Kazuo Hayashi, Department of Orthodontics and Dentofacial Orthopedic, School of Dentistry, Health Sciences University of Hokkaido, Kanazawa 1757, Ishikari-Tobetsu, Hokkaido 061-0293, Japan, E-mail: kazu{at}hoku-iryo-u.ac.jp
| Summary |
|---|
|
|
|---|
The purpose of this study was to demonstrate the advantage of the finite helical axis (FHA) system in the biomechanical analysis of orthodontic tooth movement by comparing it with the rectangular coordinate (XYZ) system.
Ten patients (6 females and 4 males, mean age 23 years 7 months) were selected. Maxillary canine retraction using light continuous forces of two different magnitudes (0.5 and 1 N) was used to retract the right and left maxillary canines in subjects who required maximum posterior anchorage. The findings were compared based on midpalatal implants that provided a fixed reference for measurement. The significance of the difference between the results with the two different force magnitudes was determined using Wilcoxon's signed-rank test.
With both the XYZ and the FHA system, no significant differences in the amount of distal movement of the canines over 2 months were found between the two force magnitudes. However, the results showed that the canine was likely to incline distally during tooth retraction with a force of 1 N compared with a force of 0.5 N (P < 0.05). With the FHA system, the result indicated that the canine was likely to incline palatally during tooth retraction with a force of 0.5 N compared with a force of 1 N (P < 0.05).
In this study, the combination of these two different approaches for describing tooth movement clearly showed a difference between light continuous forces of 0.5 and 1 N.
| Introduction |
|---|
|
|
|---|
An accurate understanding of orthodontic tooth movement resulting from applied mechanics is necessary for elucidating the optimum force magnitude and the type of system that should be used. Many investigators have focused on studying the optimum force magnitude for orthodontic tooth movement. Unfortunately, previous investigations on the magnitude of force or stress and the rate of tooth movement have not shown a strong positive relationship in humans or animals (Hixon et al., 1969
In orthodontics, it is important to determine what type of movement has occurred. In a planar environment, the type of movement can be analysed using the relationship between the centre of resistance (CRes) and the centre of rotation (CRot; Smith and Burstone, 1984
). The distance from the CRes to the CRot increases in proportion to the translation (bodily movement) of a tooth. Even though orthodontic tooth movement is generally 3D, a consideration of planar movement using the finite CRot is still an effective approach for clinical use. However, more detailed information on tooth movement through space is needed for biomechanical analysis.
Several morphometric and theoretical studies have been conducted based on a six-degrees-of-freedom rectangular coordinate (XYZ) system (Iwasaki et al., 2000
; Ashmore et al., 2002
; Hayashi et al., 2004a
). However, this representation varies depending on the position of the coordinate origin, the rotation sequence of the axis, and the timing of translation (Richard, 1984
). In particular, the reliability of computing rotation based on the XYZ system is poor. In one report, the average rotation ranged from –2.48 to 1.31 degrees (Ashmore et al., 2002
). A finite helical axis (FHA) can be used to solve the problems of superscription, and has been applied to the analysis of joint function (Spoor and Veldpaus, 1980
; Woltring et al., 1985
; Gallo et al., 1997
, 2000
; DeLong et al., 2002
). A new method for calculating the FHA has previously been reported and applied to the 3D analysis of orthodontic tooth movement (Hayashi et al., 2002
, 2004b
, 2005
, 2006
). An analysis of the direction vector of the FHA could provide more accurate information about tooth movement for biomechanical analysis than the XYZ system since the values of the parameters of the FHA do not change with coordinate transformations. Thus, the FHA parameters are the same for all points on a moving body at any particular time point, and this may lead to improved understanding of how to move teeth.
The purpose of this study was to demonstrate the advantage of the FHA in the biomechanical analysis of orthodontic tooth movement. Maxillary canine retraction using forces of different magnitudes was compared based on midpalatal orthodontic implants, which provided a fixed reference for measurement. Light continuous forces of two different magnitudes were used to retract the right and left maxillary canines in subjects who required maximum posterior anchorage. To obtain more detailed and accurate information, a 3D analysis of tooth movement was conducted using not only the XYZ system but also the FHA system.
| Subjects and methods |
|---|
|
|
|---|
Subjects
Ten patients (6 females and 4 males, mean age 23 years 7 months, range 19 years 4 months to 29 years 2 months) from the orthodontic clinic of Health Sciences University of Hokkaido were selected. All were informed of the experimental protocols and signed an informed consent form approved by the Institutional Review Board.
Since maximum posterior anchorage was required in all subjects, osseointegrated midpalatal implants (Institute Straumann AG, Waldenburg, Switzerland) were used. After a 3-month healing period following implant placement, impressions were obtained using a conventional technique to transfer the impression post (molar bands if necessary) to a dental cast. A 1.2 mm2 stainless steel rigid wire was soldered to mesh plates on the molar palatal surface or to molar bands and connected to the implant abutment on the casts. As a registration reference on dental casts for 3D tooth movement analysis, three markers (steel ball bearings;
2.778 mm) were soldered to the rigid wire (Figure 1a). After the laboratory procedures, rigid wire was fixed to the palatal implant. Orthodontic bands were cemented and mesh plates were bonded to the first molars. In all subjects, the maxillary first premolars were extracted as part of the treatment plan. Canine retraction was commenced approximately 4 months after implant placement.
|
Canine retraction mechanics
The labial arch was made of 0.45 mm (0.018 inch) stainless steel wire and included the second molar, first molar, second premolar, canine, and incisors. Standard edgewise brackets (Micro-LOC, Tomy International Inc., Tokyo, Japan) with a 0.022 x 0.028 inch slot were used. Two different retraction forces were produced using nickel-titanium (NiTi) closing coil springs (Sentalloy, Tomy International Inc.). The Sentalloy closing coil springs were extra light- (black) and light- (blue) grade, which the manufacturer stated provided forces of 0.5 and 1 N when stretched within a range of 3–15 mm, respectively. To confirm this characteristic, each closing coil spring was measured with a dial tension gauge (Mitutoyo, Kawasaki, Japan). The NiTi closing coil springs were engaged between the first molar tube hook and the sliding hook placed mesially on the canine bracket. A figure-of-eight ligation was used to increase anchorage of the posterior segment. In all subjects, a continuous force of 0.5 N was applied to the right maxillary canine, and 1 N to the opposite canine. The NiTi closing coil springs were stretched to a length of 12 mm weekly (Figure 1b).
Analysis of dental casts
To examine tooth movement, impressions of the maxillary arch were made at each appointment with hydrophilic vinyl polysiloxane impression material (JM Silicone, J. Morita, Tokyo, Japan) using customized acrylic impression trays lined with adhesive, and poured in a die stone (Noritake super rock, J. Morita). A 3D surface-scanning system using a slit laser beam (VMS-150RD, Unisn, Osaka, Japan) was used to measure the series of dental casts. The system consisted of a slit laser projector, two charge-coupled device cameras, an auto-rotating mounting unit, and a personal computer with post-processing software. The accuracy of this measuring device has been reported previously (Hayashi et al., 2002
): the resolution in the X-direction was 0.01 mm, and the Z-direction could be measured to within ±0.05 mm. The 3D shape data-analysis system consisted of a graphic workstation (Zx1, Intergraph, Huntsville, Alabama, USA) and data-processing and analysing software (I-DEAS, SDRC, Milford, Connecticut, USA). To estimate 3D tooth movement, a common coordinate system was established. The baseline model data (before canine movement) were orientated in a world coordinate system based on the three fixed markers and anatomic structures. Each subject's subsequent models were superimposed on the baseline model by the least-squares method using the three markers as registration structures, which were considered to be stable during treatment (a process called surface registration). To minimize registration error, the clamping cap of the osseointegrated implant was also used as a registration structure because of the possibility of deflection of the palatal bar (Figure 2). The discrepancy between images of the maxillary canine was recognized as tooth movement. A space coordinate system was established based on the anatomic shape of the clinical crown (Figure 2) and corresponded to the world coordinate system at baseline. The movement of an individual tooth could be expressed by a translation vector and a rotation matrix obtained by automatic surface registration of the 3D shapes before and after tooth movement (Hayashi et al., 2002
).
|
Tooth movement: XYZ and FHA systems
To represent the change in the position of a canine based on the XYZ system, six parameters were introduced. These were defined by the translations
x,
y, and
z, and the rotations
,
, and
, which denote the tipping, flaring, and rotation of the tooth coordinate system, respectively (Figure 3a). In this study, the sequence of rotation in the XYZ system was in the order X, Y, and Z.
|
A new method for calculating the FHA has previously been reported (Hayashi et al., 2002
|
| (1) |
|
| (2) |
|
| (3) |
Therefore, by multiplying equation (2) by AT and applying the relationship in equation (3),
|
| (4) |
|
| (5) |
|
| (6) |
When b is chosen on the FHA, a, resulting from equation (1), it is on the same axis. The distance between a and b is a translation, t, along the FHA. Next, an arbitrary point, d0, outside of the FHA was chosen, and its position after tooth movement d1 was calculated again by equation (1):
|
| (7) |
|
| (8) |
about the FHA in space is identical to the angle between d0, q', and d2. The calculated FHA parameters were the direction vector of the FHA v (vx, vy, vz), the rotation angle about the FHA
, the translation along the FHA t, and the shortest distance from the tooth coordinate origin to the FHA d (Figure 3b).
Parameters for the XYZ system were determined weekly for 2 months. Parameters for the FHA system were determined only at baseline and 2 months because the canine positions can clearly demonstrate the mechanical differences between two forces (Hayashi et al., 2006
). Tipping, flaring, and rotation angles in the XYZ system could be compared with the direction vector of the FHA weekly for 2 months. However, the direction vector of the FHA tends to change significantly from week to week. Although this means that the biomechanical forces are not uniform during the treatment period, it is difficult to compare with the XYZ system without a collinear approximation or modelling of a spline function. Therefore, for simplicity, only the parameters for the FHA system that were determined from canine positions at baseline and 2 months were used.
The significance of the difference between the results with the two different force magnitudes was determined using Wilcoxon's signed-rank test.
| Results |
|---|
|
|
|---|
XYZ system
The amount of distal movement of the canine crown tip with a light continuous force of 0.5 N was 3.16 mm over 2 months (Table 1). With a force of 1 N, this value was 3.39 mm. These values were not significantly different. Figure 4a shows the average movement profiles over time for all teeth subjected to both forces. Plots of average cumulative distal movement showed that no lag phase was associated with maxillary canines moved by 0.5 N. However, with 1 N, a distinct lag phase was evident at week 2.
|
|
The canine tipping values over 2 months were 6.99 degrees with 0.5 N and 8.22 degrees with 1 N. These values were significantly different (P < 0.05). Figure 4b depicts the average tipping profiles over time for all teeth subjected to both forces. The canine tipping angles were not increased at 2 weeks with 1 N. These results demonstrated that the observed lag phase was caused by absence of tipping movement.
The canine flaring values with a force of 1 N over 2 months were –1.39 degrees and with 0.5 N –1.54 degrees. A negative value for canine flaring indicated palatal inclination of the tooth. The canine rotation values over 2 months were 4.11 degrees with 0.5 N and 4.30 degrees with 1 N. These values were not significantly different. Figure 4c,d shows the average flaring and rotation profiles over time for all teeth subjected to both forces.
FHA system
The amount of distal movement of the canine crown tip with a light continuous force of 0.5 N calculated using the FHA system was 3.17 mm over 2 months (Table 2). With 1 N, this value was 3.38 mm. These values were almost the same as those with the XYZ system, and were not significantly different. The FHA yields a comprehensive 3D description of rigid body motion. Rotation around the FHA
is equivalent to a combination of three rotations in the XYZ system (tipping, flaring, and rotation). In this study, the amount of rotation around the FHA
over 2 months was 12.24 degrees with 0.5 N and 12.91 degrees with 1 N. These values were not significantly different. True translational movement of a rigid body can be determined by analysing the translation along the FHA t and the shortest distance from a tooth to the FHA d. On the other hand, an increase in the extent of bodily tooth movement strongly influences both t and d. However, the d value is affected more than the t value. In this study, the amount of translation along the FHA t over 2 months was 0.37 mm with 0.5 N and 0.29 mm with 1 N. Again, these values were not significantly different. The mean value of the shortest distance d from the FHA to the tooth coordinate origin calculated weekly for 2 months was 14.63 mm with 0.5 N and 14.74 mm with 1 N. These values were not significantly different.
|
The direction vector of the FHA could indicate the axis of rotation that was most affected in 3D transformation (Hayashi et al., 2004b
| Discussion |
|---|
|
|
|---|
To estimate the effective force for orthodontic tooth movement, it is important to consider not only the magnitude or type of force but also the type of mechanics used. There are two main types of canine retraction mechanics, friction (sliding) and frictionless (loop) mechanics; sliding mechanics were used in this investigation. Although several studies have demonstrated a significant decrease in friction with self-ligating brackets (Shivapuja and Berger, 1994
Although the optimal force for orthodontic tooth movement may differ for each tooth and for each individual patient, continuous low-magnitude force has been shown to be effective for tooth movement without undesirable side effects (Iwasaki et al., 2000
). Canine retraction is a common orthodontic procedure. If canine retraction is carried out with no simultaneous tipping or rotation, not only is the subsequent treatment plan facilitated but also the treatment period can be shortened. Iwasaki et al. (2000)
found that effective canine retraction could be produced with low continuous forces. Interestingly, in that study, force magnitudes of 0.18 and 0.6 N were found to produce effective tooth movement. A continuous force of 0.6 N was especially effective for canine retraction, and produced average distal tooth movement velocities of 1.27 mm/month with minimum simultaneous tipping or rotation. However, further research is required to support these results since the analysis of tooth movement in that report was based on the XYZ system and an unstable measuring reference.
During canine retraction, undesired tipping or rotation was minimized with both force magnitudes (Table 1). However, the canine retracted with a force of 1 N tended to tip distally compared with that treated with 0.5 N. While the tipping movement with 1 N (8.22 degrees) was adequately controlled, a smaller force can control undesirable side effects since the use of a smaller force may eliminate deflection of the main archwire. However, these results were obtained using the XYZ system, which means that the findings were influenced by the rotation sequence of the coordinate axis, as described previously. To establish the reliability of these results, it may be useful to compare the XYZ and FHA systems. The description of 3D motion using the FHA is independent of the chosen coordinate system since the values of the helical axis and the translation along the axis do not change with coordinate transformations. Thus, the FHA parameters are the same for all points on a moving body at any particular time point. This invariance makes it possible to compare tooth movement among different individuals.
Canine distal movement calculated using the FHA parameters was almost the same as that found using the XYZ system for both force magnitudes. This result demonstrates that the FHA parameters in this study were mathematically accurate and a valid representation of canine movement since movement of the origin was not influenced by computing rotation based on the XYZ system, i.e. the 3D distance between two arbitrary points is constant regardless of the coordinate system (description system) used. However, it is well-known that the rotational parameters and direction cosines of the FHA are sensitive to measurement errors. For each of these parameters, De Lange et al. (1990)
derived analytical relationships for their standard deviations. To estimate the measurement error in this study, these standard deviations were calculated at each movement step. Large errors can occur in calculations of FHA direction vectors for small rotations about the FHA (less than 1 degree). Even for small rotation points (within 5 per cent of all points in this study), the maximum error of the FHA direction vector was only ±0.22 degrees.
With the FHA system, there were significant differences in the mean values of the components of the direction vector of the FHA (vx and vy) between the force magnitudes of 0.5 and 1 N (Table 2). The result regarding vx means that the canine retracted with a force of 1 N clearly tended to tip distally compared with a force of 0.5 N. This supports the result with the XYZ system. The findings regarding vy mean that the canine retracted with a force of 0.5 N tended to tip palatally compared with a force of 1 N. The primary reason for this may be the difference in friction between these force magnitudes (Pratten et al., 1990
). In sliding mechanics, friction between the canine bracket and the archwire may lead to distal sliding of the main archwire. In fact, the incisors were retracted distally during canine retraction in all subjects. Distal sliding of the main archwire produces a force on the canine in a palatal direction since the anterior section of the main archwire is narrower than the posterior section.
However, it is necessary to consider the limitation of this relatively small study. An investigation with a larger sample size might be required to support the findings.
| Conclusion |
|---|
|
|
|---|
While the XYZ and FHA systems each give a comprehensive 3D description of rigid body movement, the FHA system can provide more detailed information on tooth movement. While the XYZ system may be more intuitive for the clinician, the FHA system is biomechanically correct. In this study, the combination of these two different approaches for describing tooth movement clearly showed a difference between a light continuous force of 0.5 and 1 N. While both force magnitudes were effective for canine retraction in sliding mechanics, the results suggest that a force magnitude of 0.5 N was more effective for eliminating undesirable side-effects (excessive tipping and lag phase) during canine retraction.
| Acknowledgement |
|---|
This study was supported in part by a grant from the School of Dentistry, Health Sciences University of Hokkaido, Japan.
| References |
|---|
|
|
|---|
-
Andreasen GF, Zwanziger D. A clinical evaluation of the differential force concept as applied to the edgewise bracket. American Journal of Orthodontics (1980) 78:25–40.[CrossRef][Web of Science][Medline]
Ashmore JL, Kurland BF, King GJ, Wheeler TT, Ghafari J, Ramsay DS. A 3-dimensional analysis of molar movement during headgear treatment. American Journal of Orthodontics and Dentofacial Orthopedics (2002) 121:18–29.[CrossRef][Web of Science][Medline]
Boester CH, Johnston LE. A clinical investigation of the concepts of differential and optimal force in canine retraction. Angle Orthodontist (1974) 44:113–119.[Web of Science][Medline]
De Lange A, Huiskes R, Kauer JMG. Measurement errors in roentgen-stereophotogrammetric joint-motion analysis. Journal of Biomechanics (1990) 23:259–269.[CrossRef][Web of Science][Medline]
DeLong R, Ko CC, Olson I, Hodger JS, Douglas WH. Helical axis errors affect computer-generated occlusal contact. Journal of Dental Research (2002) 81:338–343.
Gallo LM, Airoldi GB, Airoldi RL, Palla S. Description of mandibular finite helical axis pathways in asymptomatic subjects. Journal of Dental Research (1997) 76:704–713.
Gallo LM, Fushima K, Palla S. Mandibular helical axis pathways during mastication. Journal of Dental Research (2000) 79:1566–1572.
Gianelly AA. Force-induced change in the vascularity of the periodontal ligament. American Journal of Orthodontics (1969) 55:5–11.[CrossRef][Web of Science][Medline]
Hayashi K, Araki Y, Uechi J, Ohno H, Mizoguchi I. A novel method for the three-dimensional analysis of orthodontic tooth movement—calculation of rotation about and translation along the finite helical axis. Journal of Biomechanics (2002) 35:45–51.[CrossRef][Web of Science][Medline]
Hayashi K, Uechi J, Murata M, Mizoguchi I. Comparison of maxillary canine retraction with sliding mechanics and a retraction spring—a three-dimensional analysis based on a midpalatal orthodontic implant. European Journal of Orthodontics (2004a) 26:585–589.
Hayashi K, Tanaka F, Hikita K, Mizoguchi I. Basic behavior of the finite helical axis in a simple tooth movement simulation. Medical Engineering and Physics (2004b) 26:867–872.
Hayashi K, Hamaya M, Mizoguchi I. Simulation study for a finite helical axis (FHA) analysis of tooth movement. Angle Orthodontist (2005) 75:350–355.[Web of Science][Medline]
Hayashi K, DeLong R, Mizoguchi I. Comparison of the finite helical axis and the rectangular coordinate system in representing orthodontic tooth movement. Journal of Biomechanics (2006) 39:2925–2933.[CrossRef][Web of Science][Medline]
Hixon EH, Atikian H, Callow GE, McDonald HW, Tacy RJ. Optimal force, differential force, and anchorage. American Journal of Orthodontics (1969) 55:437–457.[CrossRef][Web of Science][Medline]
Iwasaki LR, Haack JE, Nickel JC, Morton J. Human tooth movement in response to continuous stress of low magnitude. American Journal of Orthodontics and Dentofacial Orthopedics (2000) 117:175–183.[CrossRef][Web of Science][Medline]
Owman-Moll P, Kurol J, Lundgren D. Effects of a doubled orthodontic force magnitude on tooth movement and root resorptions. An inter-individual study in adolescents. European Journal of Orthodontics (1996) 18:287–294.
Pilon JJ, Kuijpers-Jagtman AM, Maltha JC. Magnitude of orthodontic force and rate of bodily tooth movement. An experimental study. American Journal of Orthodontics and Dentofacial Orthopedics (1996) 110:16–23.[CrossRef][Web of Science][Medline]
Pizzoni L, Ravnholt G, Melsen B. Frictional forces related to self-ligating brackets. European Journal of Orthodontics (1998) 20:283–291.
Pratten DH, Popli K, Germane N, Gunsolley JC. Frictional resistance of ceramic and stainless steel orthodontic brackets. American Journal of Orthodontics and Dentofacial Orthopedics (1990) 98:398–403.[CrossRef][Web of Science][Medline]
Ren Y, Maltha JC, Kuijpers-Jagtman AM. Optimum force magnitude for orthodontic tooth movement. A systematic literature review. Angle Orthodontist (2003) 73:86–92.[Web of Science][Medline]
Rhee JN, Chun YS, Row J. A comparison between friction and frictionless mechanics with a new typodont simulation system. American Journal of Orthodontics and Dentofacial Orthopedics (2001) 119:292–299.[CrossRef][Web of Science][Medline]
Richard PP. Robot manipulators (1984) Tokyo: Corona Publishing.
Shivapuja PK, Berger J. A comparative study of conventional ligation and self-ligating bracket system. American Journal of Orthodontics and Dentofacial Orthopedics (1994) 106:472–480.[Web of Science][Medline]
Smith RJ, Burstone CJ. Mechanics of tooth movement. American Journal of Orthodontics (1984) 85:294–307.[CrossRef][Web of Science][Medline]
Spoor CW, Veldpaus FE. Rigid body motion calculated from spatial co-ordinates of markers. Journal of Biomechanics (1980) 13:391–393.[CrossRef][Web of Science][Medline]
Thorstenson GA, Kusy RP. Resistance to sliding of self-ligating brackets versus conventional stainless twin brackets with second-order angulation in the dry and wet (saliva) states. American Journal of Orthodontics and Dentofacial Orthopedics (2001) 120:361–370.[CrossRef][Web of Science][Medline]
Woltring HJ, Huiskes R, de Lange A, Veldpaus FE. Finite centroid and helical axis estimation from noisy landmark measurements in the study of human joint kinematics. Journal of Biomechanics (1985) 18:379–389.[CrossRef][Web of Science][Medline]
Ziegler P, Ingervall B. A clinical study of maxillary canine retraction with a retraction spring and with sliding mechanics. American Journal of Orthodontics and Dentofacial Orthopedics (1989) 95:99–106.[CrossRef][Web of Science][Medline]
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||