Frictional properties of aesthetic brackets
* Department of Orthodontics, Medical Center, University of Regensburg
** Department of Preventive and Pediatric Dentistry, University of Greifswald, Germany
Address for correspondence Dr Claudia Reicheneder, Department of Orthodontics, Medical Center, University of Regensburg, Franz-Josef-Strauß-Allee 11, 93053 Regensburg, Germany, E-mail: claudia.reicheneder{at}klinik.uni-regensburg.de
| Summary |
|---|
|
|
|---|
The purpose of this study was to compare the frictional properties of two self-ligating aesthetic brackets, Opal (Ultradent Products) and Oyster (Gestenco Int.), with those of four conventionally ligated aesthetic brackets, Transcend (3M Unitek), Inspire (Ormco), Allure (GAC Int.), and Image (Gestenco Int.). Friction was tested with different wire dimensions and qualities [stainless steel (SS) wire 0.017 x 0.025 inches; SS 0.019 x 0.025 inches; TMA 0.019 x 0.025 inches] using a Zwick testing machine. All brackets had a 0.022-inch slot and the prescription of an upper first premolar of the Roth system (tip: 0 degrees, torque: –7 degree). Each bracket/archwire combination was tested 10 times and each test was performed with a new bracket/wire sample that was pulled through twice. Additionally, two sets of 30 Opal brackets each were aged with an ageing machine under standardized conditions for 9–10 and 18–20 months, respectively. Friction of the aged brackets was tested with identical wire dimensions and qualities using the same testing procedure. All data were statistically analysed with unsigned comparisons of all bracket/wire combinations using GLM and the Games–Howell post hoc test.
The results showed Opal brackets to have the lowest frictional forces for all wire dimensions and qualities. Furthermore, friction was lower at a significant level (P
0.05) compared with all other brackets. Only the Oyster bracket had similar values in combination with a 0.019 x 0.025 inch SS wire. Aged Opal brackets showed higher values than new ones, but still lower frictional forces than the four conventional aesthetic brackets. Friction was comparable with the new Oyster bracket.
| Introduction |
|---|
|
|
|---|
The appearance of fixed orthodontic appliances has always been of particular concern in orthodontic treatment. In the 1970s, attempts to produce brackets from different aesthetic materials included the use of plastic brackets that were injection moulded from the aromatic polymer polycarbonate. Problems reported included crazing and deformation (Dobrin et al., 1975
Most studies carried out on ceramic brackets not only confirmed the problems of colouring and early fracture in torquing (Holt et al., 1991
) but also showed increased friction of ceramic brackets compared with metal brackets (Angolkar et al., 1990
; Pratten et al., 1990
; Kusy and Whitley, 1997
).
The increased use of sliding mechanics that followed the development of the pre-adjusted edgewise systems has focused interest on the effect of friction between bracket and archwire and its contribution to the resistance to tooth movement. Friction is defined as the resistance to motion when one object moves tangentially against another. Drescher et al. (1989)
calculated, in an in vitro experiment, that friction accounts for 60 per cent of the force required to produce tooth movement in several bracket/archwire combinations. The search for a bracket system with a low frictional resistance resulted in the development of self-ligating brackets.
Although the first self-ligating bracket was the Russell lock (Stolzenberg, 1935
), manufacturers and orthodontists have shown renewed interest in the development of self-ligating brackets since the mid-1970s. Two different types of self-ligating brackets were produced: those with a spring clip that pressed actively against the archwire, such as the Speed bracket, and self-ligating brackets, e.g. the Activa bracket whose self-ligating clip did not press against the wire.
The attempt to combine the benefits of both types of brackets, i.e. an acceptable aesthetic appearance for the patient as well as low friction for adequate clinical performance, resulted in the development of self-ligating aesthetic brackets such as the Opal, a new glass-filled, nickel-free, polycrystalline, self-ligating aesthetic bracket. A further product is the self-ligating Oyster bracket, that is based on a fibreglass-reinforced composite (FRC).
However, previous studies have mainly focused on the friction of conventionally ligated aesthetic brackets in comparison with metal or self-ligating metal brackets. Thus, the following question arises: how do the frictional properties of self-ligating aesthetic brackets compare with those of conventionally ligated aesthetic brackets in different bracket/archwire combinations?
Therefore, the purpose of the present study was to compare the frictional properties of four conventionally ligated aesthetic brackets with those of two self-ligating aesthetic brackets. This comparison necessitated the determination of the force required to pass three standard clinical archwires through these brackets in vitro. In addition, to determine the effects of ageing on friction, two further sets of Opal brackets were aged and tested.
| Materials and methods |
|---|
|
|
|---|
Bracket systems
Four conventionally ligated aesthetic brackets, i.e. Allure (GAC Int., Bohemia, New York, USA), Image (Gestenco Int., Gothenburg, Sweden), Inspire (Ormco, Orange, California, USA), and Transcend (3M Unitek, Monrovia, California, USA), as well as two self-ligating aesthetic brackets, Opal (Ultradent Products, South Jordan, Utah, USA) and Oyster (Gestenco Int.), were tested. While Inspire is a monocrystalline ceramic bracket, Allure and Transcend are made of polycrystalline ceramic and Image is made of FRC. The new self-ligated Opal bracket is made of a glass-filled, nickel-free polycrystalline resin, while Oyster is a self-ligating aesthetic bracket produced from a FRC polymer. Both Opal and Oyster are passive self-ligating brackets. The bracket specifications are given in Table 1. All brackets used in this study had a 0.022 x 0.028 inch slot and the prescription of an upper first premolar bracket of the Roth system with 0 degrees tip and –7 degrees torque.
|
Ten brackets of each type were ligated to rectangular archwires that came from plain strands of wire, with different dimensions and qualities. The archwires used were made of either 0.017 x 0.025 inch stainless steel (SS), 0.019 x 0.025 inch SS, or 0.019 x 0.025 inch TMA and produced by the same manufacturer (Ormco). The conventional brackets were ligated with elastic modules in order to prevent individual differences in forces resulting from the ligature wires. All brackets were treated under identical standardized conditions.
Experimental set-up
In order to simulate the effects of moisture and temperature corresponding to conditions in the oral cavity, the brackets with fixed wires were placed into SS containers with artificial saliva (SR 90, AMH Niemann, Barleben, Germany). The composition of the artificial saliva is shown in Table 2. They were kept in an oven at 37°C for 28 days.
|
The bracket bases were then dried and centrically bonded onto a round metal base that had been sandblasted to improve retention. To ensure correct positioning of the wire-bracket couples on the metal base, the following technique was used: Two identical standard edgewise 0.022 inch brackets (tip = 0 degrees; torque = 0 degrees) were bonded onto a flat aluminium plate in a straight line. This position was secured by ligating these brackets to a straight piece of a 0.022 x 0.025 inch SS wire before bonding. The plate was mounted centrically to the model table of the milling machine Degussa F2 (Degudent, Hanau, Germany). Each round metal base was fixed in the milling machine and adjusted in such a way that its centre corresponded with the centre of the tested bracket. Bracket bases were supplied with primer Transbond MIP (3M Unitek) and light curing composite, Tetric Flow (Ivoclar Vivadent, Ellwangen, Germany). The metal base-holding part of the milling machine was then lowered vertically towards the bracket base, ensuring parallelism between the metal base surface and bracket/wire couple. Finally, the composite was cured for 1 minute.
Friction was tested with a universal testing machine (Model 1446, Zwick, Ulm, Germany) by simulating the continuous tipping–uprighting sliding movement of bonded teeth (Figure 1). This set-up consisted of a metal framework that allowed rotation of the metal base bonded to the bracket/wire unit. A 12mm metal piece was attached to this metal base, from which a 250g weight was suspended to increase wire binding at the edges of the bracket during sliding. Two guide rollers were placed above and below the metal base to guide the movement of the wire.
|
Each of the rectangular wires was pulled through twice with the crosshead moving at a velocity of 12.7 mm/minute. The maximum frictional force was then measured. According to a study using a similar experimental set-up (Bednar et al., 1991
Ageing simulation
In the present study, only Opal brackets were aged because they showed the best frictional qualities. Two sets of 30 Opal brackets each were aged under standardized conditions simulating either 9- to 10-month or 18- to 20-month duration using a chewing masticator, (type Regensburg, EGO, Regensburg, Germany; Rosentritt et al., 2006
).
For the 9- to 10-month simulation, the brackets were left in the chewing simulator for 3 days, during which they were exposed to alternating cycles of 55°C warm and 5°C cold water 1100 times. The ageing period of 18–20 months included 2200 cycles of 55°C warm and 5°C cold water with the brackets remaining in the chewing simulator for 6 days. The brackets were then placed on the wires, bonded, and fixed into the testing apparatus in the same way as the new brackets. Prior to ligation to the brackets, the wires had been placed in containers with artificial saliva and kept in an oven at 37°C for 28 days in order to create comparable experimental conditions to the wires used in the comparative set-up described above. Ten brackets per wire dimension were tested and each wire was pulled through twice. The maximum frictional force of the aged Opal brackets was measured as described above.
Statistical analysis
Statistical analysis was carried out with the Statistical Package for Social Sciences, Version 12.0 for Windows (SPSS Inc., Chicago, Illinois, USA) and the results were considered as significant at P
0.05. With the chosen sample size of n = 20 per unit of analysis (bracket/archwire combination), a minimum statistical power of 0.80 was estimated for each two-sided comparison. The data were presented graphically by box and whisker-plots using SigmaPlot 10.0 (Systat Software GmbH, Erkrath, Germany). Normal distribution of the data was tested using the Kolmogorov–Smirnov test, and the homogeneity of variances with Levene's test. Since the data showed normal distribution but no homogeneity of variance, frictional forces were evaluated with unsigned comparisons of all bracket/wire combinations using Mann–Whitney's U-test and post hoc analysed using the procedure of Games–Howell for control of the multiple comparisons.
| Results |
|---|
|
|
|---|
For each bracket/wire unit tested, the two self-ligating brackets showed lower frictional forces than the four conventional brackets (Figure 2, Table 3). For each wire used, the Opal bracket displayed significantly lower frictional forces (P
0.05) for all wire dimensions and properties than any of the conventional ligated brackets.
|
|
The Opal bracket showed even lower frictional forces than the Oyster bracket. This difference was significant (P
0.001) for both the 0.017 x 0.025 inch SS and 0.019 x 0.025 inch TMA wires, but insignificant with regard to the 0.019 x 0.025 inch SS wire (P = 0.565). Nevertheless, the Oyster bracket showed excellent friction values. With regard to the two SS wire dimensions used in the study, the Oyster bracket showed less friction than any of the conventional ligated brackets. This difference was significant (P
0.001). The only exception was for the comparison between Oyster/SS 0.019 x 0.025 inch wire and Image/SS 0.019 x 0.025 inch wire, showing an insignificant difference (P = 0.072).
In comparison with the TMA wire, the Oyster bracket resulted in significantly (P
0.001) less friction than the Transcend, Inspire, and Allure brackets, and significantly (P
0.05) more friction than the Image bracket.
Ageing
In comparison with new Opal brackets, the ageing procedure of Opal brackets resulted in a greater frictional force for all dimensions and archwire qualities (Figure 3). This increase was significant for both SS wire dimensions 0.017 x 0.025 inches and 0.019 x 0.025inches (P
0.05), but not for TMA 0.019 x 0.025inches for the ageing period of 9–10 months. It was also significant (P
0.001) for the ageing period of 18–20 months for the two SS wire dimensions 0.017 x 0.025inches and 0.019 x 0.025inches, but again not for the 0.019 x 0.025inch TMA wire.
|
Comparison of the Opal brackets aged for 9–10 and 18–20 months showed an increase in frictional forces with ageing. This increase was not significant for the SS 0.019 x 0.025 inch and TMA 0.019 x 0.025 inch wires, but significant for the SS 0.017 x 0.025 inch wires (P
0.001). Nevertheless, friction of the aged Opal bracket was lower than that of the new brackets Transcend, Inspire, Allure, and Image, and thus, comparable with the new Oyster bracket.
| Discussion |
|---|
|
|
|---|
This laboratory study was designed to compare the friction produced by self-ligating and conventionally ligated aesthetic brackets. The results show that conventionally ligated aesthetic brackets produce higher friction than aesthetic self-ligating brackets. In general, the Opal bracket produced the lowest frictional force (Figure 2). Both self-ligating aesthetic systems consistently produced low levels of friction.
Frictional resistance between archwire and brackets is caused by many factors and varies according to archwire size and material (Angolkar et al., 1990
; Ireland et al., 1991
), mode of ligation (Bednar et al., 1991
; Sims et al., 1993
), angulation of the wire to the bracket (Andreasen and Quevedo, 1970
; Dickson et al., 1994
), and saliva (Kusy et al., 1991
; Downing et al., 1995
). Drescher et al. (1989)
regarded bracket width to play an inferior role in frictional forces.
In this study, friction was tested under dry conditions. The effect of lubrication by saliva on friction is controversial. Kusy et al. (1991)
, for example, regarded artificial saliva as inadequate replacement for human saliva and hence such experiments as invalid. Andreasen and Quevedo (1970)
claimed that saliva played an insignificant role, while Read-Ward et al. (1997)
concluded that the presence of human saliva had an inconsistent effect on static friction and sliding mechanics. Baker et al. (1987)
found that saliva acted as a lubricant, while Stannard et al. (1986)
and Downing et al. (1995)
reported that saliva increased friction. Thus, in the present investigation the wire/bracket couples were tested under dry conditions.
In this study, all four conventionally ligated aesthetic brackets were ligated with elastomeric modules. Prior to friction testing, the wires were incubated in artificial saliva at 37°C for 28 days to simulate the effect of temperature and humidity in the oral cavity on elastic ligatures. The duration chosen for the experiments corresponded to the amount of time that ligatures are supposed to hold an archwire in place. This method was selected on the basis of a study by Taloumis et al. (1997)
, who found that elastics ligatures, which had been stored in artificial saliva as described above, lost 43–66 per cent of their pressure in the first 24 hours. After that period, the decrease in pressure proved to be minimal and the elastics exerted almost constant pressure. Tying with SS ligatures was found to vary both inter- and intraindividually. Since Schumacher et al. (1990)
reported a considerable variation of pressure between 2 and 8 N with 0.011 inch SS ligatures, elastic ligatures were used in the present study in order to minimize variations and to standardize ligation.
Tipping is a constant phenomenon during sliding tooth movements. For this reason, teeth will tip until contact is established between the archwire and the diagonally opposite corners of the bracket wings. In order to simulate this clinical condition, rotation of the bracket and wire was permitted according to the previously described model for measuring friction.
No study thus far appears to have investigated the frictional behaviour of the new aesthetic self-ligating brackets in comparison with conventionally ligated brackets. However, metal self-ligating brackets have been tested in a considerable number of studies. Similar to the present experimental set-up, these tests allowed a free or predetermined tipping of the bracket relative to the wire during movement (second-order angulation; Bednar et al., 1991
; Sims et al., 1994
; Read-Ward et al., 1997
; Pizzoni et al., 1998
; Thorstenson and Kusy, 2001
).
Compared with these types of studies, the present results support previous investigations by Sims et al. (1994)
, Read-Ward et al. (1997)
, Pizzoni et al. (1998)
, and Thorstenson and Kusy (2001)
, who also found self-ligating brackets to produce significantly less friction than conventional brackets. Schumacher et al. (1999)
also reported reduced friction with Damon SL self-ligating brackets in comparison with conventionally designed brackets, despite the fact that this decrease was associated with negative side-effects in terms of levelling losses after completion of retraction.
However, despite similar testing conditions, the results found by Bednar et al. (1991)
were not confirmed. During their investigation of the frictional properties of the Speed self-ligating bracket compared with a conventional bracket, those authors reported increased friction for the self-ligating Speed bracket. One reason for this finding may be the fact that the effect of humidity and temperature in the oral cavity was not simulated. More important, however, is the fact that the different results are likely to be caused by the particular design of the Speed bracket. With this bracket, the wire is actively engaged by the spring clip and pressed into the slot so that a certain amount of pressure proportional to the size of the wire is exerted. In contrast, the locking cap in aesthetic self-ligating brackets just passively converts the bracket slot into a tube, and hence, no pressure is exerted on the wire.
In the present investigation, torque effects (third-order angulation) were not simulated. Even though torque effects increase friction in clinical situations, only a few studies simulating this effect are found in literature (Drescher et al., 1991
; Bourauel et al., 1992
).
Generally, friction appears to intensify with the increase of archwire diameter (Angolkar et al., 1990
), a finding supported by the results of the present research. For all bracket types, the 0.019 x 0.025 inch SS wire produced higher friction than the 0.017 x 0.025 inch SS wire.
Five of the six bracket types used in the test regimen produced higher frictional forces in combination with the 0.019 x 0.025-inch TMA wire than with the SS wire of the same dimension. This difference was significant (P
0.05) and independent of bracket material and ligation type. Only the Allure bracket showed significantly adverse results, in agreement with the study of Saunders and Kusy (1994)
, who found that this bracket, in a wet state, induced less friction with TMA wires than with SS wires. These high frictional forces are caused by the surface properties of the TMA wires. TMA has more porosities and a noticeably rougher surface than SS. These findings are in agreement with those of Angolkar et al. (1990)
and Drescher et al. (1989)
, who also observed higher frictional forces with TMA wires compared with SS wires.
Ageing was only carried out for the Opal brackets because they showed the most appropriate frictional qualities. With all types of archwires, aged Opal brackets exhibited greater frictional forces than new Opal brackets. This increase was significant for Opal brackets aged for 9–10 and 18–20 months with respect to SS wires. The negative influence of ageing on frictional behaviour may be due to abrasion of bracket material caused by alternate warm and cold cycles in the chewing simulator. This wear and tear resulted in increased surface roughness and probably in an accumulation of debris in the slot, which, in turn, increased friction. The results are in accordance with those of Riley et al. (1979)
, who found that friction of polycarbonate brackets gradually increased in distilled water due to corrosion, and the results of the study by Keith et al. (1993)
on ceramic brackets.
| Conclusion |
|---|
|
|
|---|
This in vitro study measured the frictional properties of different aesthetic brackets. The results demonstrate a difference in the friction produced by self-ligating aesthetic brackets and elastomeric tied aesthetic brackets.
- Both self-ligating aesthetic brackets had significantly lower friction than conventionally ligated aesthetic brackets with 0.017 x 0.025 and 0.019 x 0.025 inch SS wires. For the Opal bracket, significantly lower friction was found compared with conventionally ligated brackets regarding the 0.019 x 0.025-inch TMA wire.
- The Opal bracket produced the lowest level of friction for all bracket/archwire combinations. The difference was significant (P
0.05). The Opal bracket resulted in even lower frictional forces than the Oyster bracket. This difference was significant with the 0.017 x 0.025 inch SS wire and 0.019 x 0.025 inch TMA wire but insignificant with the 0.019 x 0.025 inch SS wire.
- Ageing of Opal brackets increased friction for all wire dimensions and qualities. This difference was significant for the 0.017 x 0.025 and 0.019 x 0.025 inch SS wires aged for 9–10 and 18–20 months. After ageing, Opal brackets showed lower frictional forces than most of the aesthetic brackets. Only the self-ligating new Oyster bracket showed similar results in some cases.
| Acknowledgement |
|---|
The authors are grateful to Fahid Ab Satti, Department of Orthodentics, for support with the experimental procedures and M. Rosentritt, Department of Prosthodontics, Medical Center, University of Regensburg, for his handling of the different machines during the tests. The authors would like to thank Ultradent Products for supplying the test brackets and Ormco for supplying the wires.
| References |
|---|
|
|
|---|
-
Andreasen GF, Quevedo FR. Evaluation of friction forces in the 0.022 x 0.028 edgewise bracket in vitro. Journal of Biomechanics (1970) 3:151–160.[CrossRef][ISI][Medline]
Angolkar PV, Kapila S, Duncanson MG, Nanda RS. Evaluation of friction between ceramic brackets and orthodontic wires of four alloys. American Journal of Orthodontics and Dentofacial Orthopedics (1990) 98:499–506.[ISI][Medline]
Baker KL, Nieberg LG, Weimer AD, Hanna M. Frictional changes in force values caused by saliva substitution. American Journal of Orthodontics and Dentofacial Orthopedics (1987) 91:316–320.[CrossRef][ISI][Medline]
Bednar JR, Gruendeman GW, Sandrik JL. A comparative study of frictional forces between orthodontic brackets and arch wires. American Journal of Orthodontics and Dentofacial Orthopedics (1991) 100:513–522.[ISI][Medline]
Bourauel C, Drescher D, Thier M. An experimental apparatus for the simulation of three-dimensional movements in orthodontics. Journal of Biomedical Engineering (1992) 14:371–378.[CrossRef][ISI][Medline]
Dickson JA, Jones SP, Davies EH. A comparison of the frictional characteristics of five initial alignment wires and stainless steel brackets at three bracket to wire angulations—an in vitro study. British Journal of Orthodontics (1994) 21:15–22.[Abstract]
Dobrin RJ, Kamel IL, Musich DR. Load-deformation characteristics of polycarbonate orthodontic brackets. American Journal of Orthodontics (1975) 67:24–33.[CrossRef][ISI][Medline]
Downing A, McCabe JF, Gordon PH. The effect of artificial saliva on the frictional forces between orthodontic brackets and archwires. British Journal of Orthodontics (1995) 22:41–46.[Abstract]
Drescher D, Bourauel C, Schumacher HA. Frictional forces between bracket and arch wire. American Journal of Orthodontics and Dentofacial Orthopedics (1989) 96:397–404.[CrossRef][ISI][Medline]
Drescher D, Bourauel C, Thier M. Orthodontisches Meß- und Simulationssystem (OMSS) für die statische und dynamische Analyse der Zahnbewegung. Fortschritte der Kieferorthopädie (1991) 52:133–140.[CrossRef][Medline]
Holt MH, Nanda RS, Duncanson MG. Fracture resistance of ceramic brackets during arch wire torsion. American Journal of Orthodontics and Dentofacial Orthopedics (1991) 99:287–293.[CrossRef][ISI][Medline]
Ireland AJ, Sherriff M, McDonald F. Effect of bracket and wire composition on frictional forces. European Journal of Orthodontics (1991) 13:322–328.
Keith O, Jones SP, Davies EH. The influence of bracket material, ligation force and wear on frictional resistance of orthodontic brackets. British Journal of Orthodontics (1993) 20:109–115.[Abstract]
Kusy RP, Whitley JQ. Friction between different wire-bracket configurations and materials. Seminars in Orthodontics (1997) 3:166–177.[CrossRef][Medline]
Kusy RP, Whitley JQ, Prewitt MJ. Comparison of the frictional coefficients for selected archwire-bracket slot combinations in the dry and wet states. Angle Orthodontist (1991) 61:293–302.[ISI][Medline]
Pizzoni L, Ravnholt G, Melsen B. Frictional forces related to self-ligating brackets. European Journal of Orthodontics (1998) 20:283–291.
Pratten DH, Popli K, Germane N, Gunsolley JC. Frictional resistance of ceramic and stainless steel orthodontic brackets. American Journal of Orthodontics and Dentofacial Orthopedics (1990) 98:398–403.[CrossRef][ISI][Medline]
Read-Ward GE, Jones SP, Davies EH. A comparison of self-ligating and conventional orthodontic bracket systems. British Journal of Orthodontics (1997) 24:309–317.[Abstract]
Riley JL, Garrett SG, Moon PC. Frictional forces of ligated plastic and edgewise brackets. Journal of Dental Research (1979) 58:98. (Abstract).
Rosentritt M, Behr M, Gebhard R, Handel G. Influence of stress simulation parameters on the fracture strength of all-ceramic fixed-partial dentures. Dental Materials (2006) 22:176–182.[CrossRef][ISI][Medline]
Saunders CR, Kusy RP. Surface topography and frictional characteristics of ceramic brackets. American Journal of Orthodontics and Dentofacial Orthopedics (1994) 106:76–87.[ISI][Medline]
Schumacher HA, Bourauel C, Drescher D. Das Friktionsverhalten von Keramikbrackets bei der bogengeführten Zahnbewegung. Fortschritte der Kieferorthopädie (1990) 51:259–265.[CrossRef][Medline]
Schumacher HA, Bourauel C, Drescher D. The influence of bracket design on frictional losses in the bracket/arch wire system. Journal of Orofacial Orthopedics (1999) 60:335–347.[CrossRef][Medline]
Sims AP, Waters NE, Birnie DJ. A comparison of the forces required to produce tooth movement ex vivo through three types of pre-adjusted brackets when subjected to determined tip or torque values. British Journal of Orthodontics (1994) 21:367–373.[Abstract]
Sims AP, Waters NE, Birnie DJ, Pethybridge RJ. A comparison of the forces required to produce tooth movement in vitro using two self-ligating brackets and a pre-adjusted bracket employing two types of ligation. European Journal of Orthodontics (1993) 15:377–385.
Stannard JG, Gau JM, Hanna MA. Comparative friction of orthodontic wires under dry and wet conditions. American Journal of Orthodontics and Dentofacial Orthopedics (1986) 89:485–491.[ISI]
Stolzenberg J. The Russell attachment and its improved advantages. International Journal of Orthodontia and Dentistry for Children (1935) 21:837–840.[CrossRef]
Taloumis LJ, Smith TM, Hondrum SO, Lorton L. Force decay and deformation of orthodontic elastomeric ligatures. American Journal of Orthodontics and Dentofacial Orthopedics (1997) 111:1–11.[CrossRef][ISI][Medline]
Taylor NG, Ison K. Frictional resistance between orthodontic brackets and archwires in the buccal segments. Angle Orthodontist (1996) 66:215–222.[ISI][Medline]
Thorstenson GA, Kusy RP. Resistance to sliding of self-ligating brackets versus conventional stainless steel twin brackets with second-order angulation in the dry and wet (saliva) states. American Journal of Orthodontics and Dentofacial Orthopedics (2001) 120:361–370.[CrossRef][ISI][Medline]
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||