The European Journal of Orthodontics 2007 29(3):299-303; doi:10.1093/ejo/cjm017
This Article
Right arrow Abstract Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow All Versions of this Article:
29/3/299    most recent
cjm017v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Elekdag-Turk, S.
Right arrow Articles by Sarac, D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Elekdag-Turk, S.
Right arrow Articles by Sarac, D.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author 2007. Published by Oxford University Press on behalf of the European Orthodontic Society. All rights reserved. For permissions, please email: journals.permissions@oxfordjournals.org.

The effect of a light-emitting diode on shear bond strength of ceramic brackets bonded to feldspathic porcelain with different curing times

Selma Elekdag-Turk*, Y. Sinasi Sarac**, Tamer Turk* and Duygu Sarac**

* Department of Orthodontics, Faculty of Dentistry, University of Ondokuz Mayis, Samsun, Turkey
** Department of Prosthodontics, Faculty of Dentistry, University of Ondokuz Mayis, Samsun, Turkey

Address for correspondence Dr Selma Elekdag-Turk, University of Ondokuz Mayis, Faculty of Dentistry, Department of Orthodontics, 55139 Kurupelit, Samsun, Turkey. E-mail: turkset{at}superonline.com


    Summary
 Top
 Summary
 Introduction
 Material and methods
 Results
 Discussion
 Conclusion
 References
 
The aim of this study was to evaluate different curing times of a light-emitting diode (LED) unit on shear bond strength (SBS) of ceramic brackets bonded to feldspathic porcelain.

Ceramic brackets were bonded with a light-cured adhesive to 96 feldspathic porcelain facets. Air-borne particle abrasion was performed using 25 µm aluminium trioxide (Al2O3) with an air abrasion device from a distance of approximately 10 mm at a pressure of 2.5 bars for 4 seconds, then the porcelain surfaces were etched with 9.6 per cent hydrofluoric acid for 2 minutes. After surface preparation of the porcelain specimens, silane was applied. In groups 1 and 2, the adhesive was cured with a quartz–tungsten–halogen (QTH) unit for 10 and 20 seconds, respectively. The LED was used in the standard mode for 3, 5, and 10 seconds for groups 3, 4, and 5, respectively. For the other three groups, the LED was used in the fast mode for 3, 5, and 10 seconds, respectively. The SBS of the brackets was measured on a universal testing machine. The adhesive remnant index (ARI) scores, damage to the porcelain, and fracture of the ceramic bracket bases were determined.

No significant differences were observed for SBS between the eight groups (P = 0.087). There was no significant difference between the groups’ ARI scores, porcelain damage, and bracket base fracture (P = 0.340, P = 0.985, and P = 0.340, respectively). There was a greater frequency of ARI scores of 0 for all groups. Fifty per cent of the porcelain facets displayed damage. Nineteen ceramic bracket base fractures were observed.

No significant difference was found for the SBS of the groups with QTH and LED units and curing times. It is reliable to use LED with a 3-second curing time since it provided adequate bond strength for ceramic brackets bonded to porcelain surfaces.


    Introduction
 Top
 Summary
 Introduction
 Material and methods
 Results
 Discussion
 Conclusion
 References
 
Bonding with light-cured adhesives has become popular among orthodontists because of their ease of use and the time they allow for precise bracket positioning (Oyama et al., 2004Go; Mavropoulos et al., 2005Go).

The most common visible light-curing unit still used by orthodontists is the quartz–tungsten–halogen (QTH) unit (Mavropoulos et al., 2005Go). Nevertheless, this technology has limitations (Yoon et al., 2002Go; Silta et al., 2005Go) with the QTH less than 1 per cent of the total energy input is converted into light, the rest is generated as heat. This heat causes degradation of the bulb, filter, and reflector over time. With an ageing light-curing unit, adhesives will be less well cured, with poorer physical properties, and an increased risk of bond failure (Cacciafesta et al., 2002Go). Halogen bulbs have a limited effective lifetime of around 50 hours (Mills et al., 1999Go). To overcome these limitations of QTH, Mills (1995)Go proposed using solid-state light-emitting diode (LED) technology. As electrical current flows through the semiconductor chips, it is converted into light, with little energy lost as heat. LEDs have an expected lifetime of several thousand hours without significant degradation of light intensity over time (Stahl et al., 2000Go).

Nowadays, there is a worldwide trend for more adults to request orthodontic treatment. Furthermore, due to superior biocompatibility and aesthetic appeal, all ceramic materials are preferred as restorative materials (Anusavice, 1996Go). Thus, the orthodontist is often faced with bonding ceramic brackets to feldspathic porcelain, which is generally used for contouring the all-ceramic copings (Anusavice, 1996Go). Bonding to porcelain is a challenge, as optimal bonding, shown to be 6–8 MPa (Reynolds, 1975Go), must be achieved to prevent bond failure.

With the introduction of LED, bond strengths of metal brackets cured with this light source and QTH have been evaluated (Cacciafesta et al., 2002Go; Dunn and Taloumis, 2002Go; Bishara et al., 2003Go; Swanson et al., 2004; Usumez et al., 2004Go; Cacciafesta et al., 2005Go; Mavropoulos et al., 2005Go; Silta et al., 2005Go). However, these investigations had variable curing times such as 6, 10, 20, and 40 seconds with QTH and 5, 6, 10, 20, and 40 seconds with LED. Research investigating the bond strength between ceramic brackets and porcelain surfaces is limited (Whitlock et al., 1994Go; Kocadereli et al., 2001Go; Harari et al., 2003Go). No studies evaluating the relationship between bond strengths of ceramic brackets and curing time with QTH and LED or evaluating different curing times with LED to bond ceramic brackets to porcelain were found in the literature.

The purpose of this study was to evaluate the effects of different curing modes and curing times of an LED on the bond strength of ceramic brackets to feldspathic porcelain.


    Material and methods
 Top
 Summary
 Introduction
 Material and methods
 Results
 Discussion
 Conclusion
 References
 

Porcelain facets

Ninety-six feldspathic (Vitadur Alpha; Vita Zahnfabrik, Bad Säckingen, Germany) porcelain specimens (10 x 10 x 3 mm) were fabricated and glazed according to the manufacturer's recommendations and mounted with autopolymerizing acrylic resin (Meliodent; Heraeus Kulzer Ltd, Newbury, Berkshire, UK).

One type of surface conditioning was applied to all specimens. Air-borne particle abrasion was performed using 25 µm aluminium trioxide (Al2O3) with an air abrasion device (TopTec; Bego, Bremen, Germany) from a distance of approximately 10 mm at a pressure of 2.5 bars for 4 seconds. The porcelain surfaces were then etched with 9.6 per cent hydrofluoric acid (Porcelain Etch Gel; Pulpdent, Watertown, Massachusetts, USA) for 2 minutes. After surface preparation of the porcelain specimens, silane (Bond Enhancer; Pulpdent) was applied.


Brackets used

Ceramic brackets for upper central incisors (Fascination 2; Dentaurum, Ispringen, Germany) were used. The base of this polycrystalline ceramic bracket is button structured and silane coated. The bracket base area is 9.43 mm2.


Curing light

Ninety-six feldspathic porcelain surface-conditioned specimens were randomly divided into eight groups, each containing 12 specimens. Adhesive primer (TransbondTM XT; 3M Unitek, Monrovia, California, USA) was applied to the conditioned porcelain surfaces. A light-cure microfilled resin (TransbondTM XT; 3M Unitek) was applied to the bracket base. The bracket was positioned manually on the porcelain surface. Excess composite was removed with an explorer. The surface conditioning and bracket placement were performed by one operator (SET).

Conventional QTH (Hilux 200; Benlioglu Dental Inc., Ankara, Turkey) and LED (Ledmax 1055; Benlioglu Dental Inc.) units were used with different curing times. In groups 1 and 2, the curing time for QTH was 10 and 20 seconds, respectively, directly through the bracket. The QTH had a light intensity of 600 mW/cm2 and a wavelength of 400–500 nm. LED was used in the standard mode for 3, 5, and 10 seconds for groups 3, 4, and 5, respectively, and for groups 6, 7, and 8, the LED was used in the fast mode for 3, 5, and 10 seconds, respectively (Table 1). The light intensity of the LED was 1500 mW/cm2 for the fast curing mode and 1200 mW/cm2 for the standard curing mode. For both curing modes, the wavelength was 440–490 nm. During light exposure, the light guide tip was placed perpendicular and immediately above the bracket with the colour-coded holders in place. The distance between the light guide tip and bracket base was approximately 5 mm.


View this table:
[in this window]
[in a new window]

 
Table 1 The groups in the study.

 

Shear bond strength

All specimens were stored in distilled water at 37 ± 2°C for 1 week and were thermocycled 500 times between 5 and 55°C with a dwelling time of 30 seconds. Shear bond testing was performed with a universal testing device (Lloyd LRX; Lloyd Instruments Ltd, Fareham, Hants, UK) at a crosshead speed of 1 mm/minute. The bond strengths were calculated in megapascals.


Residual adhesive and bracket base fracture

The surfaces of the porcelain facets were examined with a stereomicroscope (Stemi 2000-C; Carl Zeiss, Göttingen, Germany) at a magnification of x10 to determine the amount of composite resin remaining according to the adhesive remnant index (ARI; Årtun and Bergland, 1984Go), and to assess the damage to the porcelain facets. Furthermore, the porcelain facets were examined for any ceramic bracket remnants, i.e. for any ceramic bracket base fractures.


Statistical analysis

Shear bond strength (SBS) data were subjected to one-way analysis of variance (ANOVA) to test for differences between the groups. The chi-square test evaluated differences in ARI scores, porcelain facet damage, and ceramic bracket base fractures between the groups. All statistical analyses were performed at the 0.05 level of significance.


    Results
 Top
 Summary
 Introduction
 Material and methods
 Results
 Discussion
 Conclusion
 References
 
Descriptive statistics and the results of the one-way ANOVA comparing the SBS of ceramic brackets bonded to porcelain facets with the two different light sources are given in Table 2. There was no evidence to suggest a difference in SBS between any of the eight groups tested (P = 0.087).


View this table:
[in this window]
[in a new window]

 
Table 2 Descriptive statistics and the results of one-way analysis of variance comparing shear bond strengths of the eight groups tested.

 
Frequency distribution and the results of the chi-square analysis of the ARI scores, porcelain damage, and fracture of ceramic bracket bases are given in Table 3. There was no significant difference between any of the groups’ ARI scores, damage to porcelain, or fracture of ceramic bracket bases (P = 0.340, P = 0.985, and P = 0.340, respectively). There was a greater frequency of ARI scores of 0 (no adhesive on the porcelain facet) for all groups, which indicated that failures were mainly at the adhesive–porcelain interface. Approximately 50 per cent of the porcelain facets displayed damage. Nineteen partial ceramic bracket base fractures were observed.


View this table:
[in this window]
[in a new window]

 
Table 3 Frequency distribution and the results of the chi-square analysis of the adhesive remnant index (ARI) and porcelain facet damage and bracket base fracture.

 

    Discussion
 Top
 Summary
 Introduction
 Material and methods
 Results
 Discussion
 Conclusion
 References
 
The results show that type of light-cure unit and curing time did not affect SBS. Clinically, bonded brackets should be able to withstand forces generated by the treatment mechanics and occlusion and yet allow easy debonding without damage to the teeth (Ostertag et al., 1991Go; Merrill et al., 1994Go). A tensile bond strength value of 6–8 MPa would be adequate to resist treatment forces (Reynolds, 1975Go). In this study, the SBS values obtained with the QTH and LED at different curing times were above this clinically acceptable level.

The bond strength of ceramic brackets depends upon the retention mechanism of the bracket base and the type of adhesive. Nkenke et al. (1997)Go and Weinberger et al. (1997)Go reported that silanation of ceramic brackets results in significantly higher bond strength values, whereas Ostertag et al. (1991)Go and Merrill et al. (1994)Go stated that silanation of ceramic brackets does not result in higher bond strength when compared with mechanically retained ceramic brackets. Highly filled adhesives, such as Transbond XT light-cure adhesive, provide higher bond strength values (Zachrisson and Brobakken, 1978Go; Bishara et al., 1995Go). Several studies have used Transbond XT adhesive with QTH for 10 seconds; SBS values obtained with mechanically retained polycrystalline brackets ranged from 10.4 to 28.5 MPa (Bishara et al., 1997Go; Mundstock et al., 1999Go; Klocke et al., 2003Go; Theodorakopoulou et al., 2004Go; Liu et al., 2005Go; Speer et al., 2005Go). In the present study, the SBS values were 15.72 and 16.91 MPa with QTH for 10 and 20 seconds, respectively. These two values are lower than the SBS values cited by Theodorakopoulou et al. (2004)Go of 21.67 MPa and Speer et al. (2005)Go of 28.5 MPa but higher than the SBS values obtained by Liu et al. (2005)Go of 11.83 MPa, Mundstock et al. (1999)Go of 13.27 MPa, Klocke et al. (2003)Go of 10.73 MPa, and Bishara et al. (1997)Go of 10.4 MPa. In the present study, curing with QTH for 10 and 20 seconds served as the control groups. These results show that curing with QTH for 20 seconds does not have any advantage when compared with curing for 10 seconds.

To test the effectiveness of LED, curing times of 3, 5, and 10 seconds were selected. For ceramic brackets, the recommended curing time with Transbond XT adhesive is 5 seconds with an LED. SBS values obtained with 3 and 10 seconds did not show any significant differences from those values obtained with 5 seconds of curing. The SBS values at 3, 5, and 10 seconds with the LED were not significantly different from those with a QTH at 10 and 20 seconds. Cacciafesta et al. (2002)Go and Silta et al. (2005)Go did not observe any significant differences between 10 and 6 seconds with QTH and LED units. Usumez et al. (2004)Go reported that the bond strength obtained with QTH for 40 seconds and LED for 20 and 40 seconds were not significantly different. Mavropoulos et al. (2005)Go stated that the bond strength obtained with QTH for 40 seconds and LED for 10 seconds did not show significant differences. However, significantly lower bond strength was reported with LED for 10 and 5 seconds by Usumez et al. (2004)Go and Mavropoulos et al. (2005)Go, respectively. In those two studies, the light intensity of QTH was higher than that of the LED.

One factor affecting the degree of polymerization is the intensity of light. In the present study, the light intensity of the LED was higher than that of the QTH. Furthermore, the polymerization of light-cured resin depends not only on the quantity of light but also on the quality, such as wavelength (Yoon et al., 2002Go). The majority of light-activated composites contain camphoroquinone (CQ), and its absorbance strongly affects polymerization (Yoon et al., 2002Go). The 450- to 490-nm wavelength range is the optimal absorption bandwidth of CQ (Nomoto et al., 1994Go). The emission bandwidth of the LED used in this study lies between 440 and 490 nm, which coincides with the optimal absorption bandwidth of CQ. Although the curing times with the LED (3 and 5 seconds) were shorter than those of the QTH (10 and 20 seconds), the similarity of SBS values for the LED and QTH units might be explained by the higher light intensity and precise wavelength of the LED.

Factors such as the orientation of the light tip might affect light intensity. For maximum light intensity, the light guide tip should be orientated perpendicular to the bracket base. If the light guide is tipped, the circular spot changes to an ellipse resulting in decreased light intensity (Oyama et al., 2004Go). In the present study, the light tip was orientated perpendicular to the bracket base to minimize spot-area changes. Another factor affecting polymerization is light transmittance of the ceramic bracket. An extremely low percentage of light transmittance has been found for polycrystalline brackets as opposed to monocrystalline brackets (Eliades et al., 1995Go). Furthermore, a decrease in light transmittance caused by the colour-coded holders was observed. In the present study, the colour-coded holders were not removed to simulate the clinical situation. Nevertheless, the bond strengths of the two units used with different curing times exceeded the minimum bond strength value of 6–8 MPa. Eliades et al. (1995)Go mentioned that a critical transmittance value exists which provides sufficient light intensity for adequate bond strength.

The results for the 3-second curing time with LED are very encouraging. The findings of laboratory studies should not be extrapolated to clinical performance but serve as an important preliminary screening tool before clinical validation (Swanson et al., 2004Go). Thus, the effectiveness of a 3-second curing time with LED should be clinically tested.

A higher frequency of ARI score 0 was observed for all groups, indicating that no adhesive was left on the porcelain facets. This implies that the mode of failure was at the adhesive/porcelain facet interface, and that the risk of porcelain facet fracture is increased. Fifty per cent of porcelain facets in each group showed damage. Studies investigating the bond strength of ceramic brackets bonded to porcelain facets showed no damage caused by debonding (Whitlock et al., 1994Go; Harari et al., 2003Go). In those studies, mean tensile bond strengths ranged from 3.8 to 7.7 MPa and mean SBS from 1.8 to 7.5 MPa. In the present investigation, the SBS values ranged from 14.22 to 16.91 MPa. It is reported that if bond strengths between the porcelain facet and the composite resin are higher than 13 MPa, cohesive failures are observed at the porcelain facet (Thurmond et al., 1994Go). Liu et al. (2005)Go and Mundstock et al. (1999)Go noted enamel fractures on five to six teeth bonded with polycrystalline brackets, respectively. Bishara et al. (1995)Go observed enamel cracks in 33.3 per cent of teeth after debonding. They stated that this was to be expected since the more the force applied during debonding, the greater the stress transmitted to the enamel surface and the higher the incidence of enamel cracks.

In the present research, partial bracket base fracture was observed in 19 out of the 96 ceramic brackets. The inherent brittleness of the ceramic bracket may cause it to fracture on debonding. Ceramic bracket materials elongate less than 1 per cent before fracturing and, hence, cannot be ‘peeled’ off the adhesive. Brackets that fracture on debonding usually leave significant amounts of ceramic material on the tooth (Merrill et al., 1994Go).


    Conclusion
 Top
 Summary
 Introduction
 Material and methods
 Results
 Discussion
 Conclusion
 References
 
Within the limitations of this in vitro study, the following conclusions were drawn:

  1. No significant difference was found for the SBS of the groups with the QTH and LED units and curing times.
  2. A greater frequency of ARI score 0 was observed for all groups, indicating that no adhesive was left on the porcelain facets. In each group, 50 per cent of porcelain facets showed damage.
  3. It is reliable to use a LED with a 3-second curing time since it provides adequate bond strength for ceramic brackets bonded to porcelain surface.


    References
 Top
 Summary
 Introduction
 Material and methods
 Results
 Discussion
 Conclusion
 References
 

    Anusavice K J. Phillips’ science of dental materials (1996) Philadelphia: WB Saunders.

    Årtun J, Bergland S. Clinical trials with crystal growth conditioning as an alternative to acid-etch enamel pretreatment. American Journal of Orthodontics (1984) 85:333–340.[CrossRef][Web of Science][Medline]

    Bishara SE, Fonseca JM, Boyer DB. The use of debonding pliers in the removal of ceramic brackets: force levels and enamel cracks. American Journal of Orthodontics and Dentofacial Orthopedics (1995) 108:242–248.[CrossRef][Web of Science][Medline]

    Bishara SE, Olsen ME, VonWald L. Evaluation of debonding characteristics of a new collapsible ceramic bracket. American Journal of Orthodontics and Dentofacial Orthopedics (1997) 112:552–559.[CrossRef][Web of Science][Medline]

    Bishara SE, Ajlouni R, Oonsombat C. Evaluation of a new curing light on the shear bond strength of orthodontic brackets. Angle Orthodontist (2003) 73:431–435.[Web of Science][Medline]

    Cacciafesta V, Sfondrini MF, Jost-Brinkmann PG, Boehme A. Light-emitting diode technology for orthodontic bonding. Journal of Clinical Orthodontics (2002) 36:461–465.[Medline]

    Cacciafesta V, Sfondrini MF, Scribante A, Boehme A, Jost-Brinkmann PG. Effect of light-tip distance on the shear bond strengths of composite resin. Angle Orthodontist (2005) 75:386–391.[Web of Science][Medline]

    Dunn WJ, Taloumis LJ. Polymerization of orthodontic resin cement with light-emitting diode curing units. American Journal of Orthodontics and Dentofacial Orthopedics (2002) 122:236–241.[CrossRef][Web of Science][Medline]

    Eliades T, Johnston WM, Eliades G. Direct light transmittance through ceramic brackets. American Journal of Orthodontics and Dentofacial Orthopedics (1995) 107:11–19.[CrossRef][Web of Science][Medline]

    Harari D, Shapira-Davis S, Gillis I, Roman I, Redlich M. Tensile bond strength of ceramic brackets bonded to porcelain facets. American Journal of Orthodontics and Dentofacial Orthopedics (2003) 123:551–554.[CrossRef][Web of Science][Medline]

    Klocke A, Korbmacher HM, Huck LG, Ghosh J, Kahl-Nieke B. Plasma arc curing of ceramic brackets: an evaluation of shear bond strength and debonding characteristics. American Journal of Orthodontics and Dentofacial Orthopedics (2003) 124:309–315.[CrossRef][Web of Science][Medline]

    Kocadereli I, Canay S, Akca K. Tensile bond strength of ceramic orthodontic brackets bonded to porcelain surfaces. American Journal of Orthodontics and Dentofacial Orthopedics (2001) 119:617–620.[CrossRef][Web of Science][Medline]

    Liu JK, Chung CH, Chang CY, Shieh DB. Bond strength and debonding characteristics of a new ceramic bracket. American Journal of Orthodontics and Dentofacial Orthopedics (2005) 128:761–765.[CrossRef][Web of Science][Medline]

    Mavropoulos A, Staudt CB, Kiliaridis S, Krejci I. Light curing time reduction: in vitro evaluation of new intensive light-emitting diode curing units. European Journal of Orthodontics (2005) 27:408–412.[Abstract/Free Full Text]

    Merrill SW, Oesterle LJ, Hermesch CB. Ceramic bracket bonding: a comparison of shear, tensile, and torsional bond strengths of ceramic brackets. American Journal of Orthodontics and Dentofacial Orthopedics (1994) 106:290–297.[CrossRef][Web of Science][Medline]

    Mills RW. Blue light emitting diodes—another method of light curing? British Dental Journal (1995) 178:169.[Web of Science][Medline]

    Mills RW, Jandt KD, Ashworth SH. Dental composite depth of cure with halogen and blue light emitting diode technology. British Dental Journal (1999) 186:388–391.[CrossRef][Web of Science][Medline]

    Mundstock KS, Sadowsky PL, Lacefield W, Bae S. An in vitro evaluation of a metal reinforced orthodontic ceramic bracket. American Journal of Orthodontics and Dentofacial Orthopedics (1999) 116:635–641.[CrossRef][Web of Science][Medline]

    Nkenke E, Hirschfelder U, Martus P, Eberhard H. Evaluation of the bond strength of different bracket-bonding systems to bovine enamel. European Journal of Orthodontics (1997) 19:259–270.[Abstract/Free Full Text]

    Nomoto R, Uchida K, Hirasawa T. Effect of light intensity on polymerization of light-cured composite resins. Dental Materials Journal (1994) 13:198–205.[Medline]

    Ostertag AJ, Dhuru VB, Ferguson DJ, Meyer RA Jr. Shear, torsional, and tensile bond strengths of ceramic brackets using three adhesive filler concentrations. American Journal of Orthodontics and Dentofacial Orthopedics (1991) 100:251–258.[Web of Science][Medline]

    Oyama N, Komori A, Nakahara R. Evaluation of light curing units used for polymerization of orthodontic bonding agents. Angle Orthodontist (2004) 74:810–815.[Web of Science][Medline]

    Reynolds IR. A review of direct orthodontic bonding. British Journal of Orthodontics (1975) 2:171–178.

    Silta YT, Dunn WJ, Peters CB. Effect of shorter polymerization times when using the latest generation of light-emitting diodes. American Journal of Orthodontics and Dentofacial Orthopedics (2005) 128:744–748.[CrossRef][Web of Science][Medline]

    Speer C, Zimny D, Hopfenmueller W, Holtgrave EA. Bond strength of disinfected metal and ceramic brackets: an in vitro study. Angle Orthodontist (2005) 75:836–842.[Web of Science][Medline]

    Stahl F, Ashworth SH, Jandt KD, Mills RW. Light-emitting diode (LED) polymerisation of dental composites: flexural properties and polymerisation potential. Biomaterials (2000) 21:1379–1385.[CrossRef][Web of Science][Medline]

    Swanson T, Dunn WJ, Childers DE, Taloumis LJ. Shear bond strength of orthodontic brackets bonded with light-emitting diode curing units at various polymerization times. American Journal of Orthodontics and Dentofacial Orthopedics (2004) 125:337–341.[CrossRef][Web of Science][Medline]

    Theodorakopoulou LP, Sadowsky PL, Jacobson A, Lacefield W Jr. Evaluation of the debonding characteristics of 2 ceramic brackets: an in vitro study. American Journal of Orthodontics and Dentofacial Orthopedics (2004) 125:329–336.[CrossRef][Web of Science][Medline]

    Thurmond JW, Barkmeier WW, Wilwerding TM. Effect of porcelain surface treatments on bond strengths of composite resin bonded to porcelain. Journal of Prosthetic Dentistry (1994) 72:355–359.[CrossRef][Web of Science][Medline]

    Usumez S, Buyukyilmaz T, Karaman AI. Effect of light-emitting diode on bond strength of orthodontic brackets. Angle Orthodontist (2004) 74:259–263.[Web of Science][Medline]

    Weinberger SJ, Foley TF, McConnell RJ, Wright GZ. Bond strengths of two ceramic brackets using argon laser, light, and chemically cured resin systems. Angle Orthodontist (1997) 67:173–178.[Web of Science][Medline]

    Whitlock BO III, Eick JD, Ackerman RJ, Glaros AG, Chappell RP. Shear strength of ceramic brackets bonded to porcelain. American Journal of Orthodontics and Dentofacial Orthopedics (1994) 106:358–364.[Web of Science][Medline]

    Yoon TH, Lee YK, Lim BS, Kim CW. Degree of polymerization of resin composites by different light sources. Journal of Oral Rehabilitation (2002) 29:1165–1173.[CrossRef][Web of Science][Medline]

    Zachrisson BU, Brobakken BO. Clinical comparison of direct versus indirect bonding with different bracket types and adhesives. American Journal of Orthodontics (1978) 74:62–78.[CrossRef][Web of Science][Medline]


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?



This Article
Right arrow Abstract Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow All Versions of this Article:
29/3/299    most recent
cjm017v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Elekdag-Turk, S.
Right arrow Articles by Sarac, D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Elekdag-Turk, S.
Right arrow Articles by Sarac, D.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?