The European Journal of Orthodontics Advance Access originally published online on July 25, 2005
The European Journal of Orthodontics 2005 27(5):477-483; doi:10.1093/ejo/cji051
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
An in vitro comparison of the shear bond strength of a resin-reinforced glass ionomer cement and a composite adhesive for bonding orthodontic brackets
* Department of Orthodontics, Faculty of Dentistry, University of Oslo, ** NIOM Scandinavian Institute of Dental Materials, Oslo, Norway
Address for correspondence Professor Bjørn Øgaard, Department of Orthodontics, Faculty of Dentistry, University of Oslo, PO Box 1109 Blindern, N-0317 Oslo, Norway. E-mail: bogaard{at}odont.uio.no
| Summary |
|---|
|
|
|---|
The shear bond strength (SBS) of a light-cured, resin-reinforced glass ionomer and a composite adhesive in combination with a self-etching primer was compared after different setting times to evaluate when orthodontic wires could be placed. Additionally, the fracture site after debonding was assessed using the Adhesive Remnant Index (ARI). Eighty freshly extracted human premolars were used. Twenty teeth were randomly assigned to each of four groups: (1) brackets bonded with Transbond XT with a Transbond Plus etching primer and debonded within 5 minutes; (2) brackets bonded with Fuji Ortho LC and debonded within 5 minutes; (3) brackets bonded as for group 1 and debonded within 15 minutes; (4) brackets bonded as for group 2 and debonded within 15 minutes. The SBS of each sample was determined with an Instron machine.
The mean SBS were, respectively: (1) 8.8 ± 2 MPa; (2) 6.6 ± 2.5 MPa; (3) 11 ± 1.6 MPa and (4) 9.6 ± 1.6 MPa. Interpolating the cumulative fracture probability by means of a Weibull analysis, the 10 per cent probabilities of fracture for the groups were found to be attained for shear stresses of 6.1, 3.1, 8.3 and 7.1 MPa, respectively. Chi-square testing of the ARI scores revealed that the nature of the remnant did not vary significantly with time, but the type of bonding material could generally be distinguished in leaving more or less than 10 per cent of bonding material on the tooth. After debonding, the Transbond system was likely to leave adhesive on at least 10 per cent of the bonded area of the tooth.
The present findings indicate that brackets bonded with either Transbond XT in combination with Transbond Plus etching primer and Fuji Ortho LC had adequate bond strength at 5 minutes and were even stronger 15 minutes after initial bonding.
| Introduction |
|---|
|
|
|---|
Direct bonding of brackets and other attachments with composite resins have become a routine technique in fixed orthodontic treatment (Newman, 1965
Recently, a new acidic primer to be used for orthodontic purposes was introduced (Transbond Plus, 3M Unitek, Monrovia, California. USA). Combining conditioning and priming into a single treatment step results in improvement in both time- and cost-effectiveness for clinicians as well as for patients (White, 2001
; Asgari et al., 2002
; Buyukyilmaz et al., 2003
; Bishara et al., 2004
). One important advantage of simultaneous etching and priming is that the primer penetrates the entire depth of the etch, ensuring an excellent mechanical interlock (Buyukyilmaz et al., 2003
).
Glass ionomer cements (GICs) were introduced as dental cements by Wilson and Kent (1972)
. GICs possess many unique properties such as the ability to form chemical bonds with enamel, dentine and metal. Enamel decalcification adjacent to orthodontic attachments is a common phenomenon (Gorelick et al., 1982
, Øgaard 1989
). GICs contain significant amounts of fluoride, which may protect against enamel decalcification (Kvam et al., 1983
; Rezk-Lega et al., 1991
). They also possess the advantage of easier debond with less potential for damage to the enamel.
The introduction of resin-reinforced GICs (RRGICs) combines the advantages of conventional GICs with the physical properties of composite resins (Antonucci and Stansbury, 1989
; Mathis and Ferracane, 1989
). In vitro studies on the bond strength of RRGICs have shown low initial bond strengths which indicated that they were unsuitable for clinical use (Ashcraft et al., 1997
; Cook et al., 1996
; Øen et al., 1991
). Others (Cacciafesta et al., 1998
; Compton et al., 1992
; Komori and Ishikawa, 1997
; McCarthy and Hondrum, 1994
; Rezk-Lega and Øgaard, 1991
) concluded that these materials probably possess sufficient strength to be recommended for clinical use.
White (1986)
, Øen et al. (1991)
and Bishara et al. (1999b)
reported that GICs had a low initial bond strength, which increased within 24 hours. In comparison, the composite adhesive had a significantly greater initial bond strength that doubled within 24 hours (Bishara et al., 1999b
). However, many clinicians use these GICs routinely and claim low failure rates. The purpose of this investigation was therefore two-fold:
- To compare the bond strength of orthodontic brackets bonded with a light-cured resin RRGIC and a composite adhesive each used in combination with a self-etching primer at different time intervals, and to evaluate when archwires could be placed after bonding.
- To examine the fracture site at debond with the two different bonding systems.
| Material and methods |
|---|
|
|
|---|
Eighty extracted human premolars were collected and stored in distilled water in a refrigerator at 4°C. The buccal surfaces were examined for cracks and other defects using a Wild Photomacroscope M-400 (Wildheerbrugg Ltd, Heerbrugg, Switzerland). The roots of the teeth were cut off with a cooled diamond disk and the pulp chamber enlarged in order to enhance mechanical retention of the crowns in the embedding medium. The crowns were embedded in plastic moulds filled with Epofix (resin and catalyst ratio: 15 and 2 ml, respectively; Struers, Copenhagen, Denmark) up to their facial surface, which was left intact. Before testing, all buccal surfaces were polished with a rubber cup and a fluoride-free pumice, sprayed with water and dried with a compressed oil free air stream. Universal premolar brackets (Ormco edgewise wide twin slot, ref no. 340-1404, Ormco Corporation, Glendora, California, USA) were bonded to all teeth. The surface area of the bracket base was 16.1 mm2.
Two orthodontic adhesives were used: a light-cured RRGIC, Fuji Ortho LC (GC Corporation, Tokyo Japan) and a composite adhesive, Transbond XT (3M Unitek), in combination with a self-etching primer (3M Unitek). For both adhesive systems, the bonding approach followed the manufacturers' instructions. The procedure for Fuji Ortho LC included 10 per cent polyacrylic acid enamel conditioner for 20 seconds, rinsing with water and wiping the surfaces of the tooth with a moist cotton roll immediately prior to bracket bonding. The capsule containing Fuji Ortho LC was activated and mixed with an amalgamator for 10 seconds. The brackets, with adhesive, were placed on the tooth surface and light cured for 10 seconds each at the occlusal, gingival, mesial and distal sides.
The procedure for Transbond XT included application of a self-etching primer on the labial surface for 3 seconds followed by a gentle burst of oil- and moisture-free air. The brackets, with adhesive, were placed on the labial surface and light cured for 10 seconds at a time from the mesial and distal sides. The light source came from a curing light XL 3000 (3M Dental Products, Model 5530134). The original bulb was used with a minimum output light intensity of 580 mW/cm2. Before light curing, the brackets were pressed on the tooth with the bracket base perpendicular to the long axis of the crown. Excess adhesive was removed with a sharp scaler.
The teeth were randomly allocated into four groups of 20 teeth as follows:
- Group 1: Transbond XT debonded within 5 minutes of initial bonding.
- Group 2: Fuji Ortho LC debonded within 5 minutes of initial bonding.
- Group 3: Transbond XT debonded within 15 minutes of initial bonding.
- Group 4: Fuji Ortho LC debonded within 15 minutes of initial bonding.
- Group 2: Fuji Ortho LC debonded within 5 minutes of initial bonding.
The specimens were mounted in a special holding device, which was suspended in an Instron testing machine (Model 1121, Serial No. H1875, Instron Ltd, High Wycombe, Bucks, UK). An occlusal gingival load was applied to the bracket, producing a shear force at the bracket base. The shear load was applied with a crosshead speed of 1mm/minute and the force required to dislodge the bracket was measured in Newtons (N). The bond strength in MPa (N/mm2) was then calculated on the basis of a bracket area of 16.1 mm2. The handling of the materials and debonding was performed at 22.8°C at 55 per cent humidity. The analyses were carried out according to standard procedures at NIOM Scandinavian Institute of Dental Materials, Norway, and therefore no reproducibility test was performed.
The Adhesive Remnant Index (ARI) system was used to evaluate the amount of adhesive left on the labial surface after the brackets were dislodged from the prepared premolar (Oilver, 1988
) using the Photomacroscope M-400 connected to a Wild Photoautomat MPS 45.
The criteria for evaluation were:
- Score 1: All the adhesive remained on the tooth.
- Score 2: More than 90 per cent of the adhesive remained on the tooth.
- Score 3: More than 10 per cent but less than 90 per cent of the adhesive remained on the tooth.
- Score 4: Less than 10 per cent of the adhesive remained on the tooth.
- Score 5: No adhesive remained on the tooth.
- Score 2: More than 90 per cent of the adhesive remained on the tooth.
| Statistical analysis |
|---|
|
|
|---|
Descriptive statistics including the mean, standard deviation and ranges were calculated for each of the four groups tested.
Data on fracture strength can be summarized by the Weibull (1951)
distribution for the probability of fracture (pF):
![]() |
The Weibull distribution has no predictive power but can be employed to interpolate between measured data, e.g. to obtain survival probabilities justified by the number of samples tested. Estimation of the load for 10 per cent probability of failure, for example, requires a minimum of 15 specimens to be tested (ISO/TS 11405:2003).
Other statistics are available for comparing cumulative distributions without computing Weibull parameters. The KolmogorovSmirnov (KS) statistic enables a straightforward test based on the largest difference between distributions represented as cumulative probabilities (as in Figure 1). The significance to be attributed to the maximum absolute difference in probability D between the distributions is given by:
![]() |
) is evaluated numerically (Press et al., 1986
![]() |
|
A chi-square test of the ARI scores was used to assess the degree of association between the different groups.
| Results |
|---|
|
|
|---|
Shear bond strength
The descriptive statistics for the SBS are presented in Table 1. Applying the KS statistic to the cumulative distributions confirms the increase in SBS with setting time, apparent from the mean values of both products, at the 100 per cent and 98 per cent levels for Transbond XT and Fuji Ortho LC, respectively. Applying the KS statistic to a comparison of the products shows them to differ at a 95 per cent significance level after 5 minutes, and an 89 per cent level after 15 minutes setting time. Bonding with Transbond XT showed a higher mean SBS than Fuji Ortho LC after both setting times.
|
Previous experience (McCabe and Carrick, 1986
Bond failure site
Table 2 shows the fracture site at debond assessed according to the ARI system. Chi-square testing revealed an association between the type of bonding material and the setting time, but no association was apparent between the types of adhesive system.
|
Figure 2 shows both the tooth surface and bracket base of the specimens in the two different adhesive groups.
|
| Discussion |
|---|
|
|
|---|
A review of the literature identified a large variety of methods used to measure bond strength of orthodontic attachments. Therefore in the present study, the suggestions made by Fox et al. (1994)
In the oral cavity, bonded brackets are subject to either shear, tensile or torsion forces, or a combination of these. These forces are difficult to measure and hence to quantify. According to Newman (1965)
and Wheeler and Ackerman (1983)
orthodontic forces do not generally surpass 4.45 N per tooth. In another study by Reynolds and von Frauenhofer (1976)
, a minimum bond strength of 5.9 to 7.8 MPa was found adequate for most clinical orthodontic needs. Furthermore, the SBS recommended for successful clinical bonding was estimated to be 7 MPa by Lopez (1980)
. The maximum load per tooth occurring in a clinical situation is probably 17.8 N (Wheeler and Ackerman, 1983
). On the other hand, several other studies have suggested maximum bond forces of 35.6 N (Keizer et al., 1976
) and 97.88 N (Maijer and Smith, 1979
). This wide range of values is probably the result of variations in testing devices. There are no specific in vitro or in vivo tests that can be valid for all of the various clinical applications of adhesive materials.
The present findings indicate that both Fuji Ortho LC and Transbond XT in combination with a self-etching primer are adequate adhesives for bonding of orthodontic brackets. In the initial five minutes, the mean SBS of Fuji Ortho LC was 6.6 ± 2.5 MPa, which is adequate according Reynolds and von Fraunhofer (1976)
, but slightly below the bond strength recommended by Lopez (1980)
. It does, however, support the findings of a clinical study by Silverman et al. (1995)
.
On the other hand, the present findings regarding the SBS of Fuji Ortho LC disagree with those of Bishara et al. (1999b)
. They found the SBS of Fuji Ortho LC to be 0.4 ± 1.0 MPa within 30 minutes of initial bonding, compared with 6.6 ± 2.5 MPa (5 minutes) and 9.6 ± 1.5 MPa (15 minutes) in the present investigation. One possible explanation could be that the enamel surfaces were not sufficiently moist. An overly dry or desiccated enamel surface will adversely affect the bond strength. The mean SBS of Fuji Ortho LC was 9.6 ± 1.6 MPa within 15 minutes. Transbond in combination with self-etching primer had a SBS of 8.8 ± 2 MPa within 5 minutes and 11 ± 1.6 MPa within 15 minutes. These values were above those recommended by Lopez (1980)
.
The use of self-etching primers simplifies the clinical handling of adhesive systems by simultaneously combining the conditioning and priming steps (Chigira et al., 1989
; Nishida et al., 1993
; Nakabayashi, 1991
). Asgari et al. (2002)
concluded, in a clinical study, that self-etching primers such as Transbond Plus can result in fewer bond failures compared with the traditional acid-etch technique, when used for orthodontic bracket bonding. In addition, self-etching primers may save time because they combine the etching and primer steps and eliminate the need for rinsing. Arnold et al. (2002)
found that a stainless steel bracket could be bonded to enamel with a new self-etching primer (Transbond Plus self-etching primer) as an alternative to separate etching and priming. A delay of up to 10 minutes after priming and before bonding appears to have no significant effect on SBS.
Recently, Buyukyilmaz et al. (2003)
concluded, in an in vitro study, that conditioning with Transbond Plus self-etching primer before bonding orthodontic brackets with Transbond XT to the enamel surface resulted in sufficient bond strength to be recommended for clinical use. They found a higher bond strength (16 ± 4.5 MPa) compared with the present study. This difference may be due to different debonding times.
The SBS of Transbond XT with Transbond Plus self-etching primer was higher in the present study compared with Bishara et al. (1999a)
of 2.8 ± 1.9 MPa. The differences could be a result of the fact that they used a different acidic primer (Clearfil Liner Bond 2). However, Bishara et al. (1998)
, indicated that the use of acidic primers to bond orthodontic brackets to enamel surfaces can provide a clinically acceptable SBS (10.4 ± 4.4 MPa) when used with a highly (77 per cent) filled adhesive (Panavia 21). This was also confirmed recently by Bishara et al. (2004)
comparing two self-etching primers: one a no-mix and the other a two component system.
In the composite group (Transbond XT), bond failure was equally present on the tooth surface and bracket. In the GIC group (Fuji Ortho LC) bond failure was mainly at the enameladhesive interface (Table 2, Figure 2). This results in easier clean-up after debonding with the Fuji Ortho LC compared with the Transbond XT system.
| Conclusion |
|---|
|
|
|---|
The results of the present investigation indicate that both Transbond XT with Transbond Plus etching primer and Fuji Ortho LC reached adequate bond strength within 5 and 15 minutes of initial bonding. After debonding, the Transbond system was likely to leave adhesive on at least 10 per cent of the bonded area of the tooth. However, as with any in vitro study, caution must be exercised when attempting to extrapolate the results to the clinical setting.
| Acknowledgement |
|---|
The authors wish to thank Dr John E. Tibballs, NIOM, for his assistance with the statistical analysis. We also express our gratitude to staff at the Scandinavian Institute of Dental Materials, Oslo, Norway, for their generous assistance and collaboration.
| References |
|---|
|
|
|---|
-
Antonucci J M, Stansbury J W 1989 Polymer modified glass ionomer cements. Journal of Dental Research 68: 555 (abstract)
Arnold R W, Combe E C, Warford Jr J H 2002 Bonding of stainless steel brackets to enamel with a new self-etching primer. American Journal of Orthodontics and Dentofacial Orthopedics 122: 274276[CrossRef][Web of Science][Medline]
Asgari S, Salas A, English J, Powers J 2002 Clinical evaluation of bond failure rates with a new self-etching primer. Journal of Clinical Orthodontics 36: 687689
Ashcraft D B, Staley R N, Jakobsen J R 1997 Fluoride release and shear bond strengths of three light-cured glass ionomer cements. American Journal of Orthodontics and Dentofacial Orthopedics 111: 260265[Web of Science][Medline]
Barkmeier W W, Gwinnett A J, Shaffer S E 1985 Effects of enamel etching time on bond strength and morphology. Journal of Clinical Orthodontics 19: 3638
Bishara S E, Gordan V V, VonWald L, Olson M E 1998 Effect of an acidic primer on shear bond strength of orthodontic brackets. American Journal of Orthodontics and Dentofacial Orthopedics 114: 243247[CrossRef][Web of Science][Medline]
Bishara S E, Gordan V V, VonWald L, Jakobsen J R 1999a Shear bond strength of composite, glass ionomer and acidic primer adhesive systems. American Journal of Orthodontics and Dentofacial Orthopedics 115: 2428[CrossRef][Web of Science][Medline]
Bishara S E, VonWald L, Olsen M E, Laffoon J F 1999b Effect of time on the shear bond strength of glass ionomer and composite orthodontic adhesives. American Journal of Orthodontics and Dentofacial Orthopedics 116: 616620[CrossRef][Web of Science][Medline]
Bishara S E, Oonsombat C, Ajlouni R, Laffoon J F 2004 Comparison of the shear bond strength of two self-etch primer/adhesive systems. American Journal of Orthodontics and Dentofacial Orthopedics 125: 348350[CrossRef][Web of Science][Medline]
Brown C R L, Way D C 1978 Enamel loss during orthodontic bonding and subsequent loss during removal of filled and unfilled adhesives. American Journal of Orthodontics 74: 663671[CrossRef][Web of Science][Medline]
Buyukyilmaz T, Usumez S, Karaman A I 2003 Effect of self-etching primers on bond strength are they reliable? Angle Orthodontist 73: 6470[Web of Science][Medline]
Cacciafesta V, Bosch C, Melsen B 1998 Clinical comparison between a resin-reinforced self-cured glass ionomer cement and a composite resin for direct bonding of orthodontic brackets. Part 1: Wetting with water. Clinical Orthodontics and Research 1: 2936[Medline]
Carstensen W 1986 Clinical results after direct bonding of brackets using shorter etching times. American Journal of Orthodontics 89: 7072[CrossRef][Web of Science][Medline]
Chigira H, Koike T, Hasegawa T, Itoh K, Wakumoto S, Hyakawa T 1989 Effect of the self etching dentin primers on the bonding efficacy of dentin adhesive. Dental Materials Journal 8: 8692[Medline]
Compton A M, Meyers Jr C E, Hondrum S O, Lorton L 1992 Comparison of the shear bond strength of a light-cured glass ionomer and a chemically cured glass ionomer for use as an orthodontic bonding agent. American Journal of Orthodontics and Dentofacial Orthopedics 101: 138144[Web of Science][Medline]
Cook P A, Luther F, Youngson C C 1996 An in vitro study of the bond strength of light-cured glass ionomer cement in the bonding of orthodontic brackets. European Journal of Orthodontics 18: 199204
Czochrowska E, Burzykowski T, Buyukyilmaz T, Øgaard B 1999 The effect of long-term water storage on the tensile strength of orthodontic brackets bonded with resin-reinforced glass ionomer cements. Journal of Orofacial Orthopedics 60: 361370
Diedrich P 1981 Enamel alterations from bracket bonding and debonding: a study with the scanning electron microscope. American Journal of Orthodontics 79: 500522[CrossRef][Web of Science][Medline]
Durning P, McCabe J F, Gordon P H 1994 A laboratory investigation into cements used to retain orthodontic bands. British Journal of Orthodontics 21: 2732[Abstract]
Faust B J, Grego G N, Fan P L, Powers J M 1978 Penetration coefficient, tensile strength, and bond strength of thirteen direct bonding orthodontic cements. American Journal of Orthodontics 73: 512525[CrossRef][Web of Science][Medline]
Fitzpatrick D A, Way D C 1977 The effects of wear, acid etching, and bond removal on human enamel. American Journal of Orthodontics 72: 671681[CrossRef][Web of Science][Medline]
Fox N A, McCabe J F, Buckley J G 1994 A critique of bond strength testing in orthodontics. British Journal of Orthodontics 21: 3343[Abstract]
Fox N A, McCabe J F, Gordon P H 1991 Bond strengths of orthodontic bonding materials: an in-vitro study. British Journal of Orthodontics 18: 125130[Abstract]
Gorelick L 1977 Bonding metal brackets with a self-polymerizing sealant-composite: a 12-month assessment. American Journal of Orthodontics 71: 542553[CrossRef][Web of Science][Medline]
Gorelick L, Geiger A M, Gwinnett A J 1982 Incidence of white spot formation after bonding and banding. American Journal of Orthodontics 81: 9398[CrossRef][Web of Science][Medline]
Gwinnett A J, Matsui A 1967 A study of enamel adhesives. The physical relationship between enamel and adhesive. Archives of Oral Biology 12: 16151620
Johnson Jr W T, Hembree Jr J H, Weber F N 1976 Shear strength of orthodontic direct-bonding adhesives. American Journal of Orthodontics 70: 559566[CrossRef][Web of Science][Medline]
Keizer S, Ten Cate J M, Arends J 1976 Direct bonding of orthodontic brackets. American Journal of Orthodontics 69: 318327[CrossRef][Web of Science][Medline]
Kinch A P, Taylor H, Warltier R, Oliver R G, Newcombe R G 1988 A clinical trial comparing the failure rates of directly bonded brackets using etch times of 15 or 60 seconds. American Journal of Orthodontics and Dentofacial Orthopedics 94: 476483[CrossRef][Web of Science][Medline]
Komori A, Ishikawa H 1997 Evaluation of a resin-reinforced glass ionomer cement for use as an orthodontic bonding agent. Angle Orthodontist 67: 189196[Web of Science][Medline]
Kvam E, Broch J, NissenMeyer I H 1983 Comparison between a zinc phosphate cement and a glass ionomer cement for cementation of orthodontic bands. European Journal of Orthodontics 5: 307313
Lopez J I 1980 Retentive shear strengths of various bonding attachment bases. American Journal of Orthodontics 77: 669678[CrossRef][Web of Science][Medline]
Maijer R, Smith D C 1979 A new surface treatment for bonding. Journal of Biomedical Materials Research 13: 975985[CrossRef][Web of Science][Medline]
Mardaga W J, Shannon I L 1982 Decreasing the depth of etch for direct bonding in orthodontics. Journal of Clinical Orthodontics 16: 130132
Mathis R S, Ferracane J L 1989 Properties of a glass-ionomer/resin- composite hybrid material. Dental Materials 5: 355358[CrossRef][Web of Science][Medline]
McCabe J F, Carrick T E 1986 A statistical approach to the mechanical testing of dental materials. Dental Materials 2: 139142[CrossRef][Web of Science][Medline]
McCarthy M F, Hondrum S O 1994 Mechanical and bond strength properties of light-cured and chemically cured glass ionomer cements. American Journal of Orthodontics and Dentofacial Orthopedics 105: 135141[Web of Science][Medline]
Mitchell C A, O'Hagan E, Walker J M 1995 Probability of failure of orthodontic brackets bonded with different cementing agents. Dental Materials 11: 317322[CrossRef][Web of Science][Medline]
Nakabayashi N 1991 Dentinal bonding mechanisms. Quintessence International 22: 7374[Medline]
Newman G V 1965 Epoxy adhesives for orthodontic attachments: progress report. American Journal of Orthodontics 51: 901912[CrossRef][Web of Science][Medline]
Nishida K, Yamauchi J, Wada T, Hosoda H 1993 Development of a new bonding system. Journal of Dental Research 72: 137 (abstract)
Nordenvall K-J, Brännström M, Malmgren O 1980 Etching of deciduous and young and old permanent teeth. A comparison between 1560 seconds of etching. American Journal of Orthodontics 78: 99108[CrossRef][Web of Science][Medline]
Øen J O, Gjerdet N R, Wisth P J 1991 Glass ionomer cements used as bonding materials for metal orthodontic brackets. An in vitro study. European Journal of Orthodontics 13: 187191
Øgaard B 1989 Prevalence of white spot lesions in 19-year-olds: a study on untreated and orthodontically treated persons five years after treatment. American Journal of Orthodontics and Dentofacial Orthopedics 96: 423427[CrossRef][Web of Science][Medline]
Øgaard B, Bishara, S, Duschner H 2004 Enamel effects during bonding debonding and treatment with fixed appliances. In Graber T, Eliades T, Athanasiou A (eds) Risk management in orthodontics. Experts' guide to malpractice. Quintessence Publishing Company Ltd, New Malden, Surrey, UK, pp. 1947
Oilver R G 1987 The effects of differing etch times on the etch pattern on enamel of unerupted and erupted human teeth examined using the scanning electron microscope. British Journal of Orthodontics 14: 105107[Abstract]
Oilver R G 1988 The effect of different methods of bracket removal on the amount of residual adhesive. American Journal of Orthodontics and Dentofacial Orthopedics 93: 196200[CrossRef][Web of Science][Medline]
Press W H, Teukolsky S A, Vetterling W T, Flannery B P 1986 Numerical recipes : the art of scientific computing. Cambridge University Press, Cambridge, pp. 472475
Pus M D, Way D C 1980 Enamel loss due to orthodontic bonding with filled and unfilled resins using various clean-up techniques. American Journal of Orthodontics 77: 269283[CrossRef][Web of Science][Medline]
Retief D H 1973 Effect of conditioning the enamel surface with phosphoric acid. Journal of Dental Research 52: 333341
Retief D H, Dreyer C J 1967 Epoxy resins for bonding orthodontic attachments to teeth. Journal of the Dental Association of South Africa 22: 338346
Reynolds I R, Von Fraunhofer J A 1976 Direct bonding of orthodontic attachments to teeth: the relation of adhesive bond strength to gauze mesh size. British Journal of Orthodontics 3: 9195[Medline]
Rezk-Lega F, Øgaard B 1991 Tensile bond force of glass ionomer cements in direct bonding of orthodontic brackets: an in vitro comparative study. American Journal of Orthodontics and Dentofacial Orthopedics 100: 357361[Web of Science][Medline]
Rezk-Lega F, Øgaard B, Arends J 1991 An in vivo study on the merits of two glass ionomers for the cementation of orthodontic bands. American Journal of Orthodontics and Dentofacial Orthopedics 99: 162167[Web of Science][Medline]
Silverman E, Cohen M, Demke R S, Silverman M 1995 A new light-cured glass ionomer cement that bonds brackets to teeth without etching in the presence of saliva. American Journal of Orthodontics and Dentofacial Orthopedics 108: 231236[CrossRef][Web of Science][Medline]
Silverman E, Cohen M, Gianelly A A, Dietz V S 1972 A universal direct bonding system for both metal and plastic brackets. American Journal of Orthodontics 62: 236244[CrossRef][Web of Science][Medline]
Weibull W 1951 A statistical distribution function of wide applicability. Journal of Applied Mechanics 18: 293297[Web of Science]
Wheeler J J, Ackerman Jr R J 1983 Bond strength of thermally recycled metal brackets. American Journal of Orthodontics 88: 181186
White L W 1986 Glass ionomer cement. Journal of Clinical Orthodontics 20: 387391
White L W 2001 An expedited indirect bonding technique. Journal of Clinical Orthodontics 35: 3641
Wilson A D, Kent B E 1972 A new translucent cement for dentistry. The glass ionomer cement. British Dental Journal 132: 133135[CrossRef][Web of Science][Medline]
Zachrisson B U, Årtun J 1979 Enamel surface appearance after various debonding techniques. American Journal of Orthodontics 75: 121127[CrossRef][Web of Science][Medline]
This article has been cited by other articles:
![]() |
R. Valletta, D. Prisco, R. De Santis, L. Ambrosio, and R. Martina Evaluation of the debonding strength of orthodontic brackets using three different bonding systems Eur J Orthod, December 1, 2007; 29(6): 571 - 577. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||





