Skip Navigation

The European Journal of Orthodontics 2007 29(1):60-66; doi:10.1093/ejo/cjl063
This Article
Right arrow Full Text Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Vande Vannet, B.
Right arrow Articles by Wehrbein, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Vande Vannet, B.
Right arrow Articles by Wehrbein, H.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author 2007. Published by Oxford University Press on behalf of the European Orthodontic Society. All rights reserved. For permissions, please email: journals.permissions@oxfordjournals.org.

The use of three-dimensional oral mucosa cell cultures to assess the toxicity of soldered and welded wires

Bart Vande Vannet*, Jean-Louis Hanssens* and Heinrich Wehrbein**

* Department of Orthodontics, Free University of Brussels, Belgium
** Department of Orthodontics, University of Mainz, Germany

Address for correspondence Bart Vande Vannet, Department of Orthodontics, Medical and Pharmaceutical Faculty, Free University of Brussels, Laarbeeklaan 103, 1090 Brussels, Belgium, E-mail: bart.vandevannet{at}pandora.be


   Abstract

The aim of the present study was to determine whether there is a difference in toxicity and loss of viability of three-dimensional (3D) reconstructed human oral epithelium (RHOE) cell cultures induced by point-welded (PW), laser-welded (LW), and silver-soldered (SiS) orthodontic wires. Three types of soldered stainless steel (SS) wires: PW, LW, and SiS were prepared (n = 3) and subjected to multiple end-point analysis (MEA). Six pieces were cut from each wire. Each piece was placed on the triplicate cell cultures (RHOE model based on TR 146 cells). After 24 hours of topical exposure, the cell cultures were cut and stained with haematoxylin/eosin. Toxicity was assessed by evaluating the morphological changes and classifying these as mild, moderate, or severe. The in vitro cell cultures were subjected to a 3-(4,5-dimethylthiazol-2-yl)2,5-diphenyl tetrazolium bromide (MTT) assay in order to quantify viability. Copper wires served as the control to determine severe toxicity and native cell cultures were used as a baseline. Untreated SS wire (0.9 mm) was included for comparison with the welded wires.

Histological evaluation with respect to toxicity and measurement of viability in the 3D cell cultures showed no severe toxicity or loss of viability for any of the wires. The morphological ranking of the tested wires from mild to severe toxicity was: SS = PW = LW < SiS. MTT tests revealed the following mean viability values: native cell line (negative control) 98.1 per cent, SS 96.8 per cent, PW 95.5 per cent, LW 95.5 per cent, SiS 85.7 per cent, and copper wires (positive control) 51.2 per cent. Relative comparison between the different welding techniques tested on RHOE revealed, however, that LW and PW wires induced less toxicity/loss of viability compared with SiS wires.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.