Skip Navigation

The European Journal of Orthodontics 1997 19(5):543-551; doi:10.1093/ejo/19.5.543
© 1997 by European Orthodontic Society
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (3)
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Johal, A.
Right arrow Articles by Battagel, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Johal, A.
Right arrow Articles by Battagel, J.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Dental crowding: a comparison of three methods of assessment

AS Johal and JM Battagel

Department of Orthodontics, The Royal London Hospital, London, UK

This study was designed to explore a new method for the assessment of dental crowding from study models, which would be both valid and reproducible. This was then tested against two previously reported strategies.

A single examiner compared the following methods: visual examination, brass wire/callipers, and a reflex microscope with its customized computer program. Sixty study models (30 maxillary and 30 mandibular) were measured using each technique on two separate occasions.

The results showed the reflex microscope method to be the most reproducible, followed by the visual examination and brass wire methods. When testing for validity, as there is no absolutely accurate standard of arch measurement, the individual methods must be compared with one another. From the results, it was seen that the mean values for dental crowding using the reflex microscope, in both the upper and lower arches, were very close to a value which equalled the average obtained from the two means of the visual examination and brass wire methods. The results also indicated that the visual examination and brass wire methods showed a positive bias towards over- and underestimating the degree of crowding, respectively.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.