The European Journal of Orthodontics 1997 19(5):491-500; doi:10.1093/ejo/19.5.491
© 1997 by European Orthodontic Society
This Article
Right arrow FREE Full Text (PDF) Freely available
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (6)
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Bourauel, C
Right arrow Articles by Kanarachos, A
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bourauel, C
Right arrow Articles by Kanarachos, A
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Superelastic nickel titanium alloy retraction springs-an experimental investigation of force systems

C BourauelA1, D DrescherA1, J EblingA1, D BroomeA2 and A KanarachosA

A1 Department of Orthodontics, University of Bonn, Germany A2 Department of Mechanical Engineering, University College London, UK A Mechanical Design and Control Systems Section, National Technical University of Athens, Greece

The purpose of the present investigation was to study the mechanical characteristics of canine retraction springs made of superelastic nickel titanium (NiTi) alloys. A modified Burstone T-loop was used to construct an experimental canine retraction spring 10 mm in height and 10 mm in length. Twenty-five NiTi T-segments were and made from superelastic orthodontic alloys Ormco NiTi and Soar Sentalloy (dimensions 0.016 x 0.022''). The T-segments were equipped with arms made of rectangular standard steel wire (0.017 x 0.025''). The following geometrical and mechanical parameters of the retraction springs were analysed: radius and bending angles of the T-segments, distalizing force and M/F ratio during activation and the force/deflection rate of the springs. The error in the geometric parameters was in the range of 5-10 per cent, irrespective of the alloy used to produce the T-segments. On the other hand, the force systems of the springs were strongly influenced by the alloy and the batch under investigation. There were differences in the distalizing force of up to 100 per cent, i.e. at the beginning of the unloading plateau the distalizing force varied from 0.4 to 2.5 N. The force/deflection rate varied between a value of 0.06 and 0.15 N/mm, whereas the moment/force ratio reached values of 6.5-7.0 mm. Within a single batch, a reproducibility of these mechanical properties of approximately 5 per cent could be obtained. These results confirm that each orthodontic device made of superelastic NiTi alloys has to be calibrated individually. The manufacturers should pay more attention to keeping the material properties of their NiTi alloys constant.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
J. Orthod.Home page
C. Nightingale and S. P. Jones
A clinical investigation of force delivery systems for orthodontic space closure
J. Orthod., September 1, 2003; 30(3): 229 - 236.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.