Skip Navigation

The European Journal of Orthodontics 1996 18(1):131-139; doi:10.1093/ejo/18.1.131
© 1996 by European Orthodontic Society
This Article
Right arrow FREE Full Text (PDF) Freely available
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Ingervall, B.
Right arrow Articles by Bantleon, H.-P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ingervall, B.
Right arrow Articles by Bantleon, H.-P.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Moments and forces delivered by transpalatal arches for symmetrical first molar rotation

Bengt Ingervall*,, Klaus D. Honigl** and Hans-Peter Bantleon**

*Departments of Orthodontics, University of Bern Switzerland
**Departments of Orthodontics,University of Vienna Austria

Address for correspondence Prof. B. Ingervall, Klinik für Kieferorthopädie, Freiburgstrasse 7, CH-3010 Bern, Switzerland

The moments and forces delivered by round transpalatal arches of steel and of beta-titanium (TMA) for symmetrical derotation of molars were studied in laboratory experiments. Three sizes of arches were tested in two series. In the first series, the degree of activation was checked for symmetry in a computer-based strain-gauge measuring system. In the second series, the activation was carried out in a way simulating clinical use. The mesio-distal and transverse forces and the derotating moments at full activation and during derotation in steps of 5 degrees were measured.

At full activation, the steel arches delivered relatively large moments which, however, decreased rapidly during deactivation. The TMA arches had a larger working range. It was not possible to achieve full symmetry of the moments at the two ends of the arch. The difference of the two moments resulted in forces acting on the two anchorage teeth in a mesio-distal direction. These forces were generally small but could reach clinically relevant magnitude. The derotation resulted in a contractive force of up to 2.7 N which has to be compensated for by expansion. The mode of activation simulating clinical use resulted in reasonably constant forces and moments. The use of a vice to hold the arch during activation was found to be of great help and is recommended in the clinical setting. Because of the larger working range, TMA arches are recommended if substantial derotation is needed.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.