Skip Navigation

The European Journal of Orthodontics 1988 10(1):87-97; doi:10.1093/ejo/10.1.87
© 1988 by European Orthodontic Society
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Toms, A. P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Toms, A. P.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

The corrosion of orthodontic wire*

Andrew P. Toms1

Guy's Hospital, UMDS London

1Andrew Toms Senior Registrar in Orthodontics Department of Dentistry Riyadh Armed Forces Hospital PO Box 7897 Riyadh 11159 Kingdom of Saudi Arabia

The corrosion of stainless steel orthodontic wire was investigated using the electrochemical technique of polarization resistance. A potentiostat was used to apply small perturbations about the corrosion potential and the resultant current was measured. The polarization resistance is determined from the slope of the plot, and the corrosion current and rate calculated. Problems associated with the technique are non-linear polarization plots and a prior knowledge of Tafel coefficients. In the present work a non-linear optimization procedure was developed to solve the corrosion equations directly for corrosion current and Tafel coefficients.

Six sample groups were investigated, the corrosion rate expressed in terms of corrosion current density (Am–2: as received' (2.89); heat treated (2.49); finger springs (2.64); finger springs sleeved (5.78); Adams clasps (4.32) and Adams clasps sleeved (3.65). The results of the 'as received' were extremely scattered reflecting the random and uncontrollable stress imposed on the wire during the drawing process. The effect of heat treatment was to reduce the scatter and to significantly reduce the corrosion rate. The finger springs did not corrode at a significantly faster rate, but when insulated by the use of heat shrink PVC tubing leaving only the highly stressed coil to corrode, there was a two-fold increase in rate. The highly stressed Adams clasps also had a high corrosion rate.

Scanning electron micrographs of the wires before and after corrosion indicated minimal surface damage.



Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Eur J OrthodHome page
J. Daems, J.-P. Celis, and G. Willems
Morphological characterization of as-received and in vivo orthodontic stainless steel archwires
Eur J Orthod, June 1, 2009; 31(3): 260 - 265.
[Abstract] [Full Text] [PDF]


Home page
J. Orthod.Home page
G. Rahilly and N. Price
Current Products and Practice: Nickel allergy and orthodontics
J. Orthod., June 1, 2003; 30(2): 171 - 174.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.